BS EN 61000-4-34 : 2007

Current

Current

The latest, up-to-date edition.

ELECTROMAGNETIC COMPATBILITY (EMC) - PART 4-34: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS FOR EQUIPMENT WITH MAINS CURRENT MORE THAN 16 A PER PHASE

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2007

£218.00
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Test levels
6 Test instrumentation
7 Test set-up
8 Test procedures
9 Evaluation of test results
10 Test report
Annex A (normative) - Test generator current drive
        capability
Annex B (informative) - Electromagnetic environment
        classes
Annex C (informative) - Vectors for three-phase testing
Annex D (informative) - Test instrumentation
Annex E (informative) - Dip immunity tests for equipment
        with large mains current
Bibliography
Annex ZA (normative) - Normative references to
          international publications with their
          corresponding European publications

Describes the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations.

Committee
GEL/210/12
DevelopmentNote
Supersedes 03/319781 DC. (06/2007) 2007 Edition Re-Issued in February 2010 & incorporates AMD 1 2009. (03/2010)
DocumentType
Standard
Pages
38
PublisherName
British Standards Institution
Status
Current
Supersedes

EN 61000-4-30:2015/AC:2017-01 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS (IEC 61000-4-30:2015/COR1:2016)
IEC 61000-2-4:2002 Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 61000-4-14:1999+AMD1:2001+AMD2:2009 CSV Electromagnetic compatibility (EMC) - Part 4-14: Testing and measurement techniques - Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase

£218.00