BS EN 61526:2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Radiation protection instrumentation. Measurement of personal dose equivalents Hp(10) and Hp(0,07) for X, gamma, neutron and beta radiations. Direct reading personal dose equivalent meters
Hardcopy , PDF
English
30-06-2013
09-04-2026
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 Units and list of symbols
5 Mechanical characteristics
6 General characteristics
7 General test procedures
8 Additivity of indicated value
9 Radiation performance requirements and tests
10 Electrical and environmental performance
requirements and tests
11 Electromagnetic performance requirements
and tests
12 Mechanical performance, requirements and tests
13 Uncertainty
14 Documentation
15 Operation and maintenance manual
Annex A (normative) - Statistical fluctuations
Annex B (informative) - Procedure to determine the
variation of the relative response
due to radiation energy and angle
of radiation incidence
Annex C (informative) - Usage categories of personal
dosemeters
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Pertains to personal dose equivalent meters with the following characteristics: a) They are worn on the trunk or the extremities of the body; b) They measure the personal dose equivalents H[p](10) and H[p](0,07) from external X and gamma, neutron and beta radiations, and may measure the personal dose equivalent rates H[p](10) and H[p](0,07) for the same radiations (for alarming purposes); c) They have a digital indication; and d) They may have alarm functions for the personal dose equivalents or personal dose equivalent rates.
| Committee |
NCE/2
|
| DevelopmentNote |
Supersedes BS IEC 61526. (03/2007) Supersedes 00/716716 DC. (06/2007)
|
| DocumentType |
Standard
|
| Pages |
66
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
This International Standard applies to personal dose equivalent meters with the following characteristics: They are worn on the trunk or the extremities of the body. They measure the personal dose equivalents Hp(10) and Hp(0,07) from external X and gamma, neutron and beta radiations, and may measure the personal dose equivalent rates Hp (10) and Hp (0,07) for the same radiations (for alarming purposes). They have a digital indication. They may have alarm functions for the personal dose equivalents or personal dose equivalent rates. This standard is therefore applicable to the measurement of the following combinations of dose quantities (including the respective dose rates) and radiation Hp(10) and Hp(0,07) from X and gamma radiations; Hp(10) and Hp(0,07) from X, gamma and beta radiations; Hp(10) from X and gamma radiations; Hp(10) from neutron radiations; Hp(10) from X, gamma and neutron radiations; Hp(0,07) from X, gamma and beta radiations. NOTE 1 When reference is made in this standard to ”dose”, this is meant to indicate personal dose equivalent, unless otherwise stated. NOTE 2 When reference is made in this standard to ”dosemeter”, this is meant to include all personal dose equivalent meters, unless otherwise stated. This standard specifies requirements for the dosemeter and, if supplied, for its associated readout system. This standard specifies, for the dosemeters described above, general characteristics, general test procedures, radiation characteristics as well as electrical, mechanical, safety and environmental characteristics. The only requirements specified for associated readout systems are those which affect its accuracy of readout of the personal dose equivalent and alarm settings and those which concern the influence of the reader on the dosemeter. This standard also specifies in Annex C usage categories with respect to different measuring capabilities. This standard does not cover special requirements for accident or emergency dosimetry although the dosemeters may be used for this purpose. The standard does not apply to dosemeters used for measurement of pulsed radiation, such as radiation emanating from most medical diagnostic X-ray facilities, linear accelerators or similar equipment.
| Standards | Relationship |
| NF EN 61526 : 2013 | Identical |
| NBN EN 61526 : 2013 | Identical |
| I.S. EN 61526:2013 | Identical |
| DIN EN 61526:2013-09 | Identical |
| EN 61526:2013 | Identical |
| UNE-EN 61526:2013 | Equivalent |