BS EN 61557-9:2015

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Equipment for insulation fault location in IT systems

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-03-2017

Superseded date

09-04-2025

Superseded by

BS EN IEC 61557-9:2025

£272.00
Excluding VAT
Summarise this standard

1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Requirements
5 Marking and operating instructions
6 Tests
7 Overview of requirements and tests for IFLSs
Annex A (normative) - Equipment for insulation fault
        location in medical locations
Annex B (normative) - Portable equipment for insulation
        fault location
Annex C (informative) - Example of an IFLS and explanation
        of upstream and downstream system leakage
        capacitances
Bibliography
Annex ZA (normative) - Normative references to
         international publications with
         their corresponding European publications

Defines the requirements for the insulation fault location system (IFLS) which localizes insulation faults in any part of the system in unearthed IT a.c. systems and unearthed IT a.c. systems with galvanically connected d.c. circuits having nominal voltages up to 1000 V a.c., as well as in unearthed IT d.c. systems with voltages up to 1500 V d.c., independent of the measuring principle. IT systems are described in IEC 60364-4-41 amongst other literature.

Committee
PEL/85
DevelopmentNote
Supersedes 98/200252 DC. (05/2005) Supersedes 12/30274737 DC. (02/2015)
DocumentType
Standard
Pages
34
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This part of IEC61557 specifies the requirements for the insulation fault location system (IFLS) which localizes insulation faults in any part of the system in unearthed IT a.c. systems and unearthed IT a.c. systems with galvanically connected d.c. circuits having nominal voltages up to 1000V a.c., as well as in unearthed IT d.c. systems with voltages up to 1500V d.c., independent of the measuring principle. IT systems are described in IEC60364‑4‑41 amongst other literature. Additional data for a selection of devices in other standards should be noted. NOTE Further information on insulation fault location can be found in the following standards: IEC60364‑4‑41:2005, 411.6, and IEC60364‑5‑53:2001, 531.3.

Standards Relationship
IEC 61557-9:2014 Identical
NBN EN 61557-9 : 2015 COR 2016 Identical
DIN EN 61557-9 : 2015 COR 1 2017 Identical
I.S. EN 61557-9:2015 Identical
EN 61557-9:2015 Equivalent
UNE-EN 61557-9:2015 Equivalent
UNE-EN 61557-9:2010 Identical

⚠

A newer version of this standard is available.

View Current Edition
£272.00
Excluding VAT