• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

BS EN 61689:2013

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Ultrasonics. Physiotherapy systems. Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-05-2013

Withdrawn date

18-01-2023

Superseded by

BS EN IEC 61689:2022

£322.00
Excluding VAT
Summarise this standard

Committee
EPL/87
DevelopmentNote
Supersedes 93/203591 DC. (09/2005) Supersedes 04/30115966 DC. (12/2007) Supersedes 11/30230872 DC. (05/2013)
DocumentType
Standard
Pages
66
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy
Supersedes

IEC 61689:2013 is applicable to ultrasonic equipment designed for physiotherapy containing an ultrasonic transducer generating continuous or quasi-continuous wave ultrasound in the frequency range 0,5 MHz to 5 MHz. This standard only relates to ultrasonic physiotherapy equipment employing a single plane non-focusing circular transducer per treatment head, producing static beams perpendicular to the face of the treatment head. This standard specifies:
- methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on reference testing methods;
- characteristics to be specified by manufacturers of ultrasonic physiotherapy equipment based on reference testing methods;
- guidelines for safety of the ultrasonic field generated by ultrasonic physiotherapy equipment;
- methods of measurement and characterization of the output of ultrasonic physiotherapy equipment based on routine testing methods;
- and acceptance criteria for aspects of the output of ultrasonic physiotherapy equipment based on routine testing methods. Therapeutic value and methods of use of ultrasonic physiotherapy equipment are not covered by the scope of this standard. This third edition cancels and replaces the second edition published in 2007. It constitutes a technical revision which includes the following significant technical changes with respect to the previous edition:
- restriction introduced of 0,2 W/cm 2 effective intensity during hydrophone measurements for treatment heads with ka?20, to limit the likelihood of cavitation;
- change in the factor F ac, to determine the effective radiating area, from 1,354 to 1,333;
- and change to SI units for terms and definitions.

This publication is to be read in conjunction with IEC 60601-2-5:2009.

Standards Relationship
DIN EN 61689 : 2013 Identical
NBN EN 61689 : 2013 Identical
IEC 61689:2013 Identical
NF EN 61689 : 2013 Identical
EN 61689:2013 Identical
IEC TR 63084:2017 Identical
I.S. EN 61689:2013 Identical
UNE-EN 61689:2013 Equivalent
UNE-EN 61689:1999 Identical

⚠

A newer version of this standard is available.

£322.00
Excluding VAT