BS EN 61935-1:2009

Current

Current

The latest, up-to-date edition.

Specification for the testing of balanced and coaxial information technology cabling Installed balanced cabling as specified in the standards series EN 50173

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-04-2010

£348.00
Excluding VAT
Summarise this standard

INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Reference measurement procedures for electrical
  properties
5 Field test measurement requirements for electrical
  properties
6 Field tester measurement accuracy requirements
Annex A (informative) - Uncertainty and variability of
        field test results
Annex B (normative) - Reference laboratory test configuration
        for alien crosstalk testing
Annex C (informative) - General information on power sum
        alien crosstalk performance of installations
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

Describes reference measurement procedures for cabling parameters and the requirements for field tester accuracy to measure cabling parameters identified in series EN 50173.

Committee
EPL/46
DevelopmentNote
Supersedes 98/233751 DC and 00/200944 DC (04/2003) Supersedes 04/30079682 DC. (03/2006) Supersedes 06/30146603 DC. (04/2010)
DocumentType
Standard
Pages
116
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of EN 61935 specifies reference measurement procedures for cabling parameters and the requirements for field tester accuracy to measure cabling parameters identified in series EN 50173. This standard does not apply to EN 50173-4.

This International Standard applies when the cable assemblies are constructed of cables complying with the IEC 61156 family of standards, and connecting hardware as specified in IEC 60603-7 family of standards or IEC 61076-3-104 and IEC 61076-3-110. In the case where cables and/or connectors do not comply with these standards, then additional tests may be required.

This standard is organized as follows:

  • reference laboratory measurement procedures on cabling topologies are specified in Clause 4. In some cases, these procedures may be used in the field;

  • descriptions and requirements for measurements in the field are specified in Clause 5;

  • performance requirements for field testers and procedures to verify performance are specified in Clause 6.

NOTE 1 This standard does not include tests that are normally performed on the cables and connectors separately. These tests are described in IEC 61156-1 and IEC 60603-7 or IEC 61076-3-104 and IEC 61076-3-110 respectively.

NOTE 2 Wherever possible, cables and connectors used in cable assemblies, even if they are not described in IEC 61156 or IEC 60603-7, IEC 61076-3-104 or IEC 61076-3-110, are tested separately according to the tests given in the relevant generic specification. In this case, most of the environmental and mechanical tests described in this standard may be omitted.

NOTE 3 Users of this standard are advised to consult with applications standards, equipment manufacturers and system integrators to determine the suitability of these requirements for specific networking applications.

This standard relates to performance with respect to 100 Ω cabling. For 120 Ω or 150 Ω cabling, the same principles apply but the measurement system should correspond to the nominal impedance level.

Field tester types include certification, qualification and verification. Certification testing is performed for the rigorous needs of commercial/industrial buildings to this standard. Qualification testing is described in IEC 61935-3. Qualification testing determines whether the cabling will support certain network technologies (e.g., 1000BASE-T, 100BASE-TX, IEEE 1394b1)). Qualification testers do not have traceable accuracy to national standards and provide confidence that specific applications will work. Verification testers only verify connectivity.

Throughout this document, 4-pair cabling is assumed. The test procedures described in this standard may also be used to evaluate 2-pair balanced cabling. However, 2-pair cabling links that share the same sheath with other links are tested as 4-pair cabling.

Standards Relationship
EN 140101-806:2008 Identical
I.S. EN 61935-1:2009 Identical
NBN EN 61935-1 : 2010 Identical
DIN EN 61935-1 : 2010 COR 1 2012 Identical
NF EN 61935-1 : 2010 Identical
EN 61935-1:2009 Identical
UNE-EN 61935-1:2009 Equivalent

£348.00