BS EN ISO 11138-2:2017

Current

Current

The latest, up-to-date edition.

Sterilization of health care products. Biological indicators Biological indicators for ethylene oxide sterilization processes

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-04-2017

£166.00
Excluding VAT
Summarise this standard

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Test organism
6 Suspension
7 Carrier and primary packaging
8 Inoculated carriers and biological indicators
9 Population and resistance
Annex A (normative) - Method for determination of
        resistance to ethylene oxide sterilization
Annex B (informative) - Rationale for the inclusion
        of a second minimum D value specification
        as a result of changes to the test gas used
        to evaluate resistance and deletion of the
        requirement for a minimum D value at
        30 degrees C
Bibliography

Describes requirements for test organisms, suspensions, inoculated carriers, biological indicators and test methods intended for use in assessing the performance of sterilizers and sterilization processes employing ethylene oxide gas as the sterilizing agent, either as pure ethylene oxide gas or mixtures of this gas with diluent gases, at sterilizing temperatures within the range of 29 degrees C to 65 degrees C.

Committee
CH/198
DevelopmentNote
Supersedes BS EN 866-2, BS EN 866-8 & 04/30078099 DC (08/2006) Supersedes 15/30321505 DC. (04/2017)
DocumentType
Standard
Pages
18
PublisherName
British Standards Institution
Status
Current
Supersedes

This document specifies requirements for test organisms, suspensions, inoculated carriers, biological indicators and test methods intended for use in assessing the performance of sterilizers and sterilization processes employing ethylene oxide gas as the sterilizing agent, either as pure ethylene oxide gas or mixtures of this gas with diluent gases, at sterilizing temperatures within the range of 29°C to 65°C.

NOTE1 Requirements for validation and control of ethylene oxide sterilization processes are provided by ISO11135 and ISO14937 .

NOTE2 National or regional regulations can provide requirements for work place safety.