BS EN ISO 81060-1:2012

Current

Current

The latest, up-to-date edition.

Non-invasive sphygmomanometers Requirements and test methods for non-automated measurement type

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-07-2012

£306.00
Excluding VAT
Summarise this standard

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Identification and marking
5 General requirements for testing non-automated
   sphygmomanometers
6 General requirements
7 Requirements
8 Additional requirements for non-automated sphygmomanometer
   with mercury manometer
9 Non-automated sphygmomanometers with aneroid manometer
10 Cleaning, sterilization and disinfection
11 Biocompatibility
12 Information supplied by the manufacturer
Annex A (informative) - Rationale and guidance
Annex B (informative) - Advice regarding non-automated
        sphygmomanometers with a mercury manometer
Annex C (informative) - Environmental aspects
Annex D (informative) - Reference to the essential principals
Annex E (informative) - Terminology - Alphabetized index of
        defined terms
Bibliography
Annex ZA (informative) - Relationship between this European
         Standard and the Essential Requirements of EU
         Directive 93/42/EEC on medical devices

Describes requirements for non-automated sphygmomanometers, and their accessories, which, by means of inflatable cuffs, are used for the non-invasive blood pressure measurement by operator observation.

Committee
CH/205/10
DevelopmentNote
Renumbers & supersedes BS ISO 81060-1. 2012 version incorporates corrigendum to BS ISO 81060-1. Supersedes 06/30137313 DC, BS EN 1060-1, BS EN 1060-2 & 11/30251468 DC. (07/2012)
DocumentType
Standard
Pages
50
PublisherName
British Standards Institution
Status
Current
Supersedes

ISO 81060-1:2007 specifies requirements for non-automated sphygmomanometers and their accessories, which, by means of inflatable cuffs, are used for the non-invasive blood pressure measurement by operator observation. ISO 81060-1:2007 specifies requirements for the safety and essential performance, including effectiveness and labelling, for non-automated sphygmomanometers and their accessories, including test methods to determine the accuracy of non-invasive blood pressure measurement. ISO 81060-1:2007 covers non-invasive blood pressure measurement devices with a pressure-sensing element and display used in conjunction with means of detecting blood flow.

Standards Relationship
ISO 81060-1:2007 Identical
EN ISO 81060-1:2012 Identical
I.S. EN ISO 81060-1:2012 Equivalent
DIN EN ISO 81060-1:2012-08 Equivalent
UNE-EN ISO 81060-1:2012 Equivalent