Customer Support: +44 (0)203 327 3140

Your region & currency

United Kingdom English(GB)

Pricing in GBP £

Local sites

  • Shopping Cart
    There are no items in your cart

We noticed you are browsing from United States. Switch to our United States site for local pricing in USD.

Dismiss alert

BS ISO 11171:2016

Superseded

Superseded

View Superseded by

Hydraulic fluid power. Calibration of automatic particle counters for liquids

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-10-2016

Superseded date

31-07-2023

Superseded by

BS ISO 11171:2020

£322.00
Excluding VAT
Summarise this standard

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Materials and equipment
5 Sequence of APC calibration procedures
6 Sizing calibration procedure
7 Data presentation
8 Identification statement
Annex A (normative) - Preliminary APC check
Annex B (normative) - Coincidence error procedure
Annex C (normative) - Flow rate limit determination
Annex D (normative) - Resolution determination
Annex E (normative) - Verification of particle-counting accuracy
Annex F (normative) - Preparation and verification of bottles of
        secondary calibration suspensions
Annex G (informative) - APC calibration round robin
Annex H (informative) - Sample calculations
Annex I (informative) - Verification of particle size distribution
        of calibration samples
Bibliography

Describes procedures for: a) primary particle-sizing calibration, sensor resolution and counting performance of automatic particle counters (APCs) for liquids capable of analysing bottle samples; b) secondary particle-sizing calibration using suspensions verified with a primary calibrated APC; c) establishing acceptable operation and performance limits; d) verifying particle sensor performance using a truncated test dust; and e) determining coincidence and flow rate limits.

Committee
MCE/18/-/6
DevelopmentNote
Supersedes 98/700803 DC and BS 5540-2(1992). (05/2002) Supersedes 09/30171027 DC. (11/2010)
DocumentType
Standard
Pages
62
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This International Standard specifies procedures for the following: primary particle-sizing calibration, sensor resolution and counting performance of automatic particle counters (APCs) for liquids capable of analysing bottle samples; secondary particle-sizing calibration using suspensions verified with a primary calibrated APC; establishing acceptable operation and performance limits; verifying particle sensor performance using a truncated test dust; determining coincidence and flow rate limits.

Standards Relationship
ISO 11171:2016 Identical

⚠

A newer version of this standard is available.

View Current Edition
£322.00
Excluding VAT