FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Identification and classification
5 Standard ratings and service conditions
6 Requirements
7 General testing procedure
8 Type tests (design tests)
9 Routine tests and acceptance tests
10 Test requirements on polymer-housed surge arresters
11 Test requirements on gas-insulated metal enclosed
   arresters (GIS-arresters)
12 Separable and dead-front arresters
13 Liquid-immersed arresters
Annex A (normative) - Abnormal service conditions
Annex B (normative) - Test to verify thermal equivalency
        between complete arrester and arrester section
Annex C (normative) - Artificial pollution test with respect
        to the thermal stress on porcelain housed
        multi-unit metal-oxide surge arresters
Annex D (informative) - Typical information given with
        enquiries and tenders
Annex E (informative) - Ageing test procedure - Arrhenius
        law - Problems with higher temperatures
Annex F (informative) - Guide for the determination of the
        voltage distribution along metal-oxide surge arresters
Annex G (normative) - Mechanical considerations
Annex H (normative) - Test procedure to determine the
        lightning impulse discharge capability
Annex I (normative) - Determination of the start temperature
        in tests including verification of thermal stability
Annex J (normative) - Determination of the average
        temperature of a multi-unit highvoltage arrester
Annex K (informative) - Example calculation of test
        parameters for the operating duty test
        (8.7) according to the requirements of 7.3
Annex L (informative) - Comparison of the old energy
        classification system based on line
        discharge classes and the new classification
        system based on thermal energy ratings
        for operating duty tests and repetitive
        charge transfer ratings for repetitive
        single event energies
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding
         European publications

Pertains to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit voltage surges on a.c. power circuits with U[s] above 1 kV.

Committee
CT 37
DevelopmentNote
Classificazione CEI 37-2. (08/2001)
DocumentType
Standard
Pages
176
PublisherName
Comitato Elettrotecnico Italiano
Status
Current
Supersedes

Standards Relationship
IEC 60099-4:2014 Identical