INSULATORS FOR OVERHEAD LINES - COMPOSITE LINE POST INSULATORS FOR A.C. SYSTEMS WITH A NOMINAL VOLTAGE GREATER THAN 1000 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA

Available format(s)

Hardcopy , PDF

Language(s)

English - Italian

Published date

01-01-2009

£104.87
Excluding VAT

INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviations
6 Environmental conditions
7 Transport, storage and installation
8 Tolerances
9 Classification of tests
10 Design tests
11 Type tests
12 Sample tests
13 Routine tests
Annex A (informative) - Notes on the mechanical
        loads and tests
Annex B (informative) - Determination of the equivalent
        bending moment caused by combined loads
Bibliography
Annex ZA (normative) - Normative references to
         international publicationswith their
         corresponding European publications

Pertains to composite line post insulators consisting of a loadbearing cylindrical insulating solid core consisting of fibres - usually glass - in a resin-based matrix, a housing (outside the insulating core) made of polymeric material and end fittings permanently attached to the insulating core.

Committee
CT 36
DevelopmentNote
Classificazione CEI 36-29 (12/2003)
DocumentType
Standard
Pages
54
PublisherName
Comitato Elettrotecnico Italiano
Status
Current

Standards Relationship
IEC 61952:2008 Identical
EN 61952:2008 Identical

IEC 61467:2008 Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests
IEC 60050-471:2007 International Electrotechnical Vocabulary (IEV) - Part 471: Insulators
IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
IEC 60383-1:1993 Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria
EN 60383-1:1996/A11:1999 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1 KV - CERAMIC OR GLASS INSULATOR UNITS FOR A.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
ISO 3452:1984 Non-destructive testing — Penetrant inspection — General principles
IEC 61462:2007 Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations
IEC GUIDE 111:2004 Electrical high-voltage equipment in high-voltage substations - Common recommendations for product standards
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
EN 62217:2013 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
IEC 60383-2:1993 Insulators for overhead lines with a nominal voltage above 1000 V - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria
EN 60383-2:1995 Insulators for overhead lines with a nominal voltage above 1 kV - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria