• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

CISPR 16-1:1999+AMD1:2002 CSV

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

23-10-2002

Superseded date

19-11-2003

£643.02
Excluding VAT
Summarise this standard

FOREWORD
TABLE RECAPITULATING CROSS-REFERENCES
1 Scope
2 Normative references
3 Definitions
4 Measuring apparatus
   4.1 Quasi-peak measuring receivers for the frequency
        range 9 kHz to 1000 MHz
   4.2 Peak measuring receivers for the frequency range
        9 kHz to 1000 MHz
   4.3 Average measuring receivers for the frequency range
        9 kHz to 1000 MHz
   4.4 RMS measuring receivers for the frequency range 9 kHz
        to 1000 MHz
   4.5 Spectrum analyzers and scanning receivers
   4.6 Audio-frequency voltmeter
5 Ancillary apparatus
   5.1 Artificial mains networks
   5.2 Current and voltage probes
   5.3 Absorbing clamp for use in the frequency range 30 MHz
        to 1000 MHz
   5.4 Disturbance analyzers
   5.5 Antennas for measurement of radiated radio disturbance
   5.6 Test sites for measurement of radio disturbance field
        strength for the frequency range of 30 MHz to 1000 MHz
   5.7 Reverberating chamber for total radiated power measurement
   5.8 Coupling units for conducted current immunity measurement
   5.9 TEM cells for immunity to radiated disturbance measurement
   5.10 Coupling devices for measuring signal lines
   5.11 The artificial hand and series RC element
   5.12 Test sites for measurement of radio disturbance field
        strength for the frequency range 1 GHz to 18 GHz
   5.13 Specifications and validation procedures for a test
        site to be used to calibrate antennas in the frequency
        range of 30 MHz to 1000 MHz
Annex A (normative) Determination of response to repeated pulses
        of quasi-peak and r.m.s. measuring receivers (subclauses
        3.2, 4.1.4.2, 4.4.2.2 and 4.4.4.1)
Annex B (normative) Determination of pulse generator spectrum
        (subclauses 4.1.4, 4.2.4, 4.3.4, 4.4.4)
Annex C (normative) Accurate measurements of the output of
        nanosecond pulse generators (subclauses 4.1.4, 4.2.4,
        4.3.4, 4.4.4)
Annex D (normative) Influence of the quasi-peak measuring
        receiver characteristics on its pulse response
        (subclause 4.1.4.2)
Annex E (normative) Response of average and peak measuring
        receivers (subclause 4.3.2.1)
Annex F (normative) Artificial mains networks (subclause 5.1)
Annex G (normative) Validation procedure of the open area test
        site for the frequency range of 30 MHz to 1000 MHz
        (subclause 5.6)
Annex H (normative) Calibration of the absorbing clamp
        (subclause 5.3)
Annex I (informative) Construction, frequency range, and
        calibration of current probes (subclause 5.2)
Annex J (informative) Construction of the absorbing clamp
        (subclause 5.3)
Annex K (informative) Construction details for open area test
        sites in the frequency range of 30 MHz to 1000 MHz
        (subclause 5.6)
Annex L (informative) Basis for 4 dB site acceptability
        criterion (subclause 5.6)
Annex M (informative) Construction of the coupling units for
        current injection for the frequency range 0,15 MHz to
        30 MHz (subclause 5.8)
Annex N (informative) Principle of operation and examples of
        coupling units for conducted current immunity
        measurements (subclause 5.8)
Annex O (normative) Parameters of broadband antennas
Annex P (normative) Loop antenna system for magnetic field
        induced current measurements in the frequency range of
        9 kHz to 30 MHz
Annex Q (normative) Example and measurement of an asymmetrical
        artificial network (AAN)
Annex R (informative) CALTS requirements (subclause 5.13)
Annex S (informative) Test antenna considerations (subclause
        5.13)
Annex T (informative) Antenna and site attenuation theory
        (subclause 5.13)
Annex U (informative) Application of a fixed length dipole
        (30 MHz <= f <= 80 MHz) (subclause 5.13)
Annex V (informative) Pascal Program used in T.1.3 (subclause
        5.13)
Annex W (informative) Checklist validation procedure (subclause
        5.13)
Annex X (normative) Monopole (1 m rod antenna) performance
        equations and characterization of the associated antenna
        matching network
Annex Y (normative) Performance check of the exceptions from the
        definitions of a click according to 4.2.3 of CISPR 14-1
Annex Z (normative) Example and measurement of the parameters of
        the AN for coaxial and other screened cables
Figures 1 to Z.2

Specifies the characteristics and performance of equipment for the measurement of radio disturbance voltages, currents and fields in the frequency range 9 kHz to 18 GHz. In addition, requirements are specified for specialized equipment for discontinuous disturbance measurements. The requirements include the measurement of broadband and narrowband types of radio disturbance. Replaces the first edition published in 1993, amendment 1 (1997) as well as consolidated edition 1.1 (1998).

Committee
CISPR/CIS/A
DevelopmentNote
Also numbered as BS CISPR 16-1(1999) (04/2003) Supersedes CISPR 1, CISPR 2, CISPR 3, CISPR 4, CISPR 5, and CISPR 6. (07/2004)
DocumentType
Standard
Pages
422
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

£643.02
Excluding VAT