FOREWORD
SECTION 1: GENERAL
  1.1 Scope
  1.2 Normative references
  1.3 Definitions
SECTION 2: DISTURBANCE MEASUREMENTS
  2.1 Types of disturbance to be measured
      2.1.1 Types of disturbance
      2.1.2 Detector functions
  2.2 Connection of measuring equipment
      2.2.1 Connection of associated equipment
      2.2.2 Connections to RF reference ground
      2.2.3 Connection between the EUT and the artificial
            mains network
  2.3 General measurement requirements and conditions
      2.3.1 Disturbance not produced by the equipment under
            test
      2.3.2 Measurement of continuous disturbance
      2.3.3 Operating conditions of the EUT
      2.3.4 Interpretation of measuring results
      2.3.5 Measurement times and scan rates for continuous
            disturbance
  2.4 Measurement of disturbances conducted along leads, 9 kHz
      to 30 MHz
      2.4.1 Introduction
      2.4.2 Measuring equipment (receivers, etc.)
      2.4.3 Associated measuring equipment
      2.4.4 Equipment test configuration
      2.4.5 System test configuration for conducted emissions
            measurements
      2.4.6 In situ measurements
  2.5 Measurements using the absorbing clamp, 30 MHz to 1000 MHz
      2.5.1 General
      2.5.2 Measurements
  2.6 Measurement of radiated disturbances
      2.6.1 Introduction
      2.6.2 Field-strength measurements in the frequency range
            9 kHz to 1 GHz
      2.6.3 Field-strength measurements in the frequency range
            1 GHz to 18 GHz
      2.6.4 Substitution method of measurement in the frequency
            range of 30 MHz to 18 GHz
      2.6.5 Measurements of in situ equipment
      2.6.6 Measurement in a loop antenna system
SECTION 3: IMMUNITY MEASUREMENTS
  3.1 Immunity test criteria and general measurement procedures
      3.1.1 General measurement method
      3.1.2 Immunity degradation criteria
      3.1.3 Product specification details
  3.2 Method of measurement of immunity for conducted signals
      3.2.1 Coupling units
      3.2.2 Measurement set-up
      3.2.3 Method of measurement of input immunity
  3.3 Method of measurement of immunity to radiated electric
      field interference
      3.3.1 Measurements using the TEM mode
      3.3.2 Measurement using absorber-lined shielded rooms
      3.3.3 Measurements using an open area test site (OATS)
SECTION 4: AUTOMATED MEASUREMENTS
  4.1 Automated measurements of emissions
      4.1.1 Introduction: Precautions for automating
            measurements
      4.1.2 Generic measurement procedure
      4.1.3 Prescan measurements
      4.1.4 Data reduction
      4.1.5 Emission maximization and final measurement
      4.1.6 Post processing and reporting
SECTION 5: FACTORS INFLUENCING MEASUREMENT ACCURACY
  5.1 Factors influencing measurement accuracy
      5.1.1 Accuracy of measurements
      5.1.2 Avoidance of extraneous signals and effects
Annex A (informative) Guidelines to connection of electrical
                      equipment to the artificial mains
                      network (see 2.2)
Annex B (informative) Use of spectrum analyzers and scanning
                      receivers (see 2.3)
Annex C (informative) Historical background to the method of
                      measurement of the interference power
                      produced by electrical household and
                      similar appliances in the VHF rang
                      (see 3.1)
Annex D (informative) Decision tree for use of detectors for
                      conducted measurements (see 2.4.2.1)
Annex E (informative) Measurement of disturbances in the
                      presence of ambient emissions
Annex F (informative) Example of the uncertainty budget

The second part of CISPR 16 specifies the methods of measurement ofEMC phenomena in the frequency range 9kHz to 18 GHz. It deals with disturbance measurements and immunity measurements.

Committee
CISPR/CIS/A
DevelopmentNote
To be read in conjunction with CISPR 16-1. (07/2003)
DocumentType
Standard
Pages
118
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
NEN CISPR 16-2 : 1998 AMD 2 2002 Identical

£366.79
Excluding VAT