CSA/ANSI Z21.88:19 (R2024)/CSA 2.33:19 (R2024)
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Vented gas fireplace heaters
English
01-01-2019
06-06-2025
Preface This is the ninth edition of CSA/ANSI Z21.88 • CSA 2.33, Vented gas fireplace heaters . It supersedes the previous editions published in 2017, 2016, 2014, 2009, 2005, 2002, 2000, and 1998. Scope 1.1 This Standard applies to newly produced vented gas fireplace heaters (see Clause 3, Definitions), hereinafter referred to as appliance(s), constructed entirely of new, unused parts and materials, and having input ratings up to and including 400,000 Btu/hr (117 228 W): a) for use with natural gas; b) for use with propane; c) direct vent appliances for manufactured home (USA only) or mobile home OEM installation convertible for use with natural gas and propane when provision is made for simple conversion from one gas to the other [see Clause 4.1.4a) and b)]; d) direct vent appliances for manufactured home (USA only) or mobile home aftermarket installation for use with natural gas only or propane gas only [see Clause 4.1.4b)]; e) direct vent appliances for recreational vehicle installation for use with propane gas only [see Clause 4.1.4c)]; f) direct vent appliances for recreational vehicle installation only convertible for use with natural gas and propane gas when provision is made for the simple conversion from one gas to the other [see Clause 4.1.4c)]; and g) for direct vent appliances for manufactured home (USA only) or mobile home OEM installation for use with propane gas only [see Clause 4.1.4a)]. The construction of vented gas fireplace heaters and vented gas fireplace heaters with cooling units for use with the above-mentioned gases is covered under Clause 4, Construction. The performance of vented gas fireplace heaters and vented gas fireplace heaters with cooling units for use with the above-mentioned gases is covered under Clause 5, Performance. 1.2 Clauses 4and 5cover all vented gas fireplace heaters. In addition, Clauses 6and 7address the requirements specific to vented condensing gas fireplace heaters. 1.3 Annex A, Automatic intermittent pilot ignition systems or on-demand pilot ignition systems for field installation, includes provisions for newly produced (optional) automatic intermittent pilot ignition systems and on-demand pilot ignition systems (see Clause 3, Definitions), constructed entirely of new, unused parts and materials, to be adapted in the field to an appliance equipped with an existing continuous pilot burner and which has been examined and tested for compliance with this Standard when installed on the appliance. 1.4 If a value for measurement given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.5 All references to \"psi\" throughout this Standard are to be considered gauge pressures, unless otherwise specified. 1.6 Clause 9, Items unique to the United States, contains provisions that are unique to the United States. 1.7 Clause 10, Items unique to Canada, contains provisions that are unique to Canada. 1.8 This Standard also applies to appliances with draft hoods that are factory-equipped with automatic vent damper devices (see Clause 3, Definitions), hereinafter referred to as vent damper devices. 1.9 Special construction provisions applicable to vented gas fireplace heaters designed for use with an optional design-certified conversion kit are outlined under Annex B, Provisions for listed gas appliance conversion kits (optional). 1.10 Clause 2, Reference publications, contains a list of standards specifically referenced in this Standard and sources from which they may be obtained. 1.11 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
| DevelopmentNote |
This version is revised in FEBRUARY 2021
|
| DocumentType |
Standard
|
| ISBN |
978-1-4883-2239-6
|
| Pages |
274
|
| ProductNote |
THIS STANDARD ALSO REFERS TO CAN1-6.2-M81 (R2006), CAN1-6.4-M79 (R2011), CAN1-6.6-M78 (R2011), ANSI Y14.15-1975 (R1994), ANSI/ASME B52–2013, ANSI/ASME PTC 19.3-1974 (R2004) This version is revised in FEBRUARY 2021
|
| PublisherName |
Canadian Standards Association
|
| Status |
Superseded
|
| SupersededBy |
Preface This is the ninth edition of CSA/ANSI Z21.88 • CSA 2.33, Vented gas fireplace heaters . It supersedes the previous editions published in 2017, 2016, 2014, 2009, 2005, 2002, 2000, and 1998. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Joint Technical Subcommittee on Vented Gas-Fired Warm Air Heaters under the jurisdiction of the Z21/83 Technical Committee on Performance and Installation of Gas Burning Appliances and Related Accessories and the Strategic Steering Committee on Fuels and Appliances. It has been formally approved by the Z21/83 Technical Committee, the Canadian Technical Committee on Gas Appliances and Related Accessories, and the Interprovincial Gas Advisory Council. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to newly produced vented gas fireplace heaters (see Clause 3, Definitions), hereinafter referred to as appliance(s), constructed entirely of new, unused parts and materials, and having input ratings up to and including 400,000 Btu/hr (117 228 W): a) for use with natural gas; b) for use with propane; c) direct vent appliances for manufactured home (USA only) or mobile home OEM installation convertible for use with natural gas and propane when provision is made for simple conversion from one gas to the other [see Clause 4.1.4a) and b)]; d) direct vent appliances for manufactured home (USA only) or mobile home aftermarket installation for use with natural gas only or propane gas only [see Clause 4.1.4b)]; e) direct vent appliances for recreational vehicle installation for use with propane gas only [see Clause 4.1.4c)]; f) direct vent appliances for recreational vehicle installation only convertible for use with natural gas and propane gas when provision is made for the simple conversion from one gas to the other [see Clause 4.1.4c)]; and g) for direct vent appliances for manufactured home (USA only) or mobile home OEM installation for use with propane gas only [see Clause 4.1.4a)]. The construction of vented gas fireplace heaters and vented gas fireplace heaters with cooling units for use with the above-mentioned gases is covered under Clause 4, Construction. The performance of vented gas fireplace heaters and vented gas fireplace heaters with cooling units for use with the above-mentioned gases is covered under Clause 5, Performance. 1.2 Clauses 4and 5cover all vented gas fireplace heaters. In addition, Clauses 6and 7address the requirements specific to vented condensing gas fireplace heaters. 1.3 Annex A, Automatic intermittent pilot ignition systems or on-demand pilot ignition systems for field installation, includes provisions for newly produced (optional) automatic intermittent pilot ignition systems and on-demand pilot ignition systems (see Clause 3, Definitions), constructed entirely of new, unused parts and materials, to be adapted in the field to an appliance equipped with an existing continuous pilot burner and which has been examined and tested for compliance with this Standard when installed on the appliance. 1.4 If a value for measurement given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.5 All references to \"psi\" throughout this Standard are to be considered gauge pressures, unless otherwise specified. 1.6 Clause 9, Items unique to the United States, contains provisions that are unique to the United States. 1.7 Clause 10, Items unique to Canada, contains provisions that are unique to Canada. 1.8 This Standard also applies to appliances with draft hoods that are factory-equipped with automatic vent damper devices (see Clause 3, Definitions), hereinafter referred to as vent damper devices. 1.9 Special construction provisions applicable to vented gas fireplace heaters designed for use with an optional design-certified conversion kit are outlined under Annex B, Provisions for listed gas appliance conversion kits (optional). 1.10 Clause 2, Reference publications, contains a list of standards specifically referenced in this Standard and sources from which they may be obtained. 1.11 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
| NFPA 501A : 2013 | FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES, AND COMMUNITIES |
| NFPA 70 : 2014 | NATIONAL ELECTRICAL CODE |
| NFPA 54 : 2015 | NATIONAL FUEL GAS CODE |
| ASTM B 487 : 1985 : R2013 | Standard Test Method for Measurement of Metal and Oxide Coating Thickness by Microscopical Examination of Cross Section |
| ASTM A 90/A90M : 2013 | Standard Test Method for Weight [Mass] of Coating on Iron and Steel Articles with Zinc or Zinc-Alloy Coatings |
| ASTM B 499 : 2009 : R2014 | Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals |
| ASME B1.20.1 : 2013(R2018) | PIPE THREADS, GENERAL PURPOSE (INCH) |
| ASME B1.13M : 2005 : R2010 | METRIC SCREW THREADS - M PROFILE |
| ASHRAE 34 : 2013 | DESIGNATION AND SAFETY CLASSIFICATION OF REFRIGERANTS |
| NFPA 1192 : 2015 | RECREATIONAL VEHICLES |
| ASHRAE 15 : 2013 | SAFETY STANDARD FOR REFRIGERATION SYSTEMS |
| ASTM A 653/A653M : 2015 | Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process |