• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

DIN EN 50265-2-2 : 1999

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 2: PROCEDURES - SECTION 2: DIFFUSION FLAME

Published date

12-01-2013

Superseded date

01-06-2005

Superseded by

DIN EN 60332-2-2:2005-06

Sorry this product is not available in your region.

Vorwort
1 Anwendungsbereich
2 Normative Verweisungen
3 Definitionen
  3.1 Zündquelle
  3.2 Verkohlen
4 Prüfgerät
  4.1 Allgemeines
  4.2 Zündquelle
5 Prüfverfahren
  5.1 Probe
  5.2 Konditionierung
  5.3 Positionierung der Probe
  5.4 Anbringung der Flamme
6 Auswertung
Anhang A (informativ) Empfohlene Prüfanforderungen
Anhang B (informativ) Literaturhinweise

Defines the method for testing small optical fibre cables or a small insulated conductor or cable (less than 0.5 sq. mm cross-section), when the metal defined in BS EN 50265-1 is unsuitable, as some small fibre cables could break or small conductors melt during flame application.

DevelopmentNote
Supersedes DIN VDE 0472-804. (09/2004)
DocumentType
Standard
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
BS EN 50265-2-2:1999 Identical
NF EN 50265-2-2 : 1999 Identical
EN 50265-2-2:1998 Identical
VDE 0482-265-2-2 : 1999 Corresponds
NEN EN 50265-2-2 : 1999 Identical
I.S. EN 50265-2-2:1999 Identical
VDE 0482-265-2-2 : 1999 Identical
UNE-EN 50265-2-2:1999 Identical

VDE 0101 : 2000 POWER INSTALLATIONS EXCEEDING 1 KV
VDE 0482-265-2-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 2-1: PROCEDURES - 1 KW PRE-MIXED FLAME
VDE 0482-265-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 1: APPARATUS
DIN EN 50265-2-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 2-1: PROCEDURES - 1 KW PRE-MIXED FLAME
DIN EN 50265-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 1: APPARATUS

DIN EN 50265-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 1: APPARATUS
EN 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
DIN EN 60695-4 : 2013 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)
VDE 0482-265-2-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 2-1: PROCEDURES - 1 KW PRE-MIXED FLAME
VDE 0471-4 : 2013 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)
VDE 0482-265-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 1: APPARATUS
DIN EN 50265-2-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 2-1: PROCEDURES - 1 KW PRE-MIXED FLAME
EN 50265-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 1: Apparatus
EN 50265-2-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-1: Procedures - 1 kW pre-mixed flame

Sorry this product is not available in your region.