EN 1090-5:2017

Current

Current

The latest, up-to-date edition.

Execution of steel structures and aluminium structures - Part 5: Technical requirements for cold-formed structural aluminium elements and cold-formed structures for roof, ceiling, floor and wall applications

Published date

22-03-2017

Sorry this product is not available in your region.
Summarise this standard

European foreword
1 Scope
2 Normative references
3 Terms, definitions, symbols
   and abbreviations
4 Specifications and documentation
5 Constituent products
6 Manufacturing
7 Welding at the construction site
8 Mechanical Fastening
9 Erection
10 Surface protection
11 Geometrical tolerances
12 Inspection, testing and correction
Annex A (normative) - Basic requirements
        for profiled sheeting
Annex B (normative) - Additional design
        requirements for profiled sheeting
Annex C (informative) - Documentation
Annex D (normative) - Geometrical tolerances
Annex E (normative) - Galvanic corrosion
Annex F (normative) - Additional information
Bibliography

This European Standard specifies requirements for the execution i.e. the manufacture and the installation of cold-formed structural aluminium components made from profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading conditions or seismic loading conditions and their documentation. It does cover products of structural class I and II according to EN 1999-1-4 used in structures.Structural elements are understood here to mean profiled sheeting, such as trapezoidal, sinusoidal, liner trays or cassette profiles (Figure 1), that are produced by cold forming. Perforated and micro profiled sheeting are also covered by this part.Welded sections are excluded from this part and are covered by EN 1090-3 except seal welding in low-stress areas.This standard also covers spacer constructions between the outer and inner or upper and lower skins as well as supporting members for roofs, walls and ceilings made from cold-formed profiled sheeting and the connections and attachments of the afore mentioned elements as long as they are involved in load transfer, it also covers connections and attachments of these elements.A combination of steel and aluminium structural elements are permitted, e.g. liner trays made of steel, stiffened by profiles made of aluminium. In this case, EN 1090-4 and this document apply.Composite structural elements where the interaction between dissimilar materials are an integral part of the structural behaviour such as sandwich panels and composite floors are not covered by this standard.NOTEThe structures covered in this standard can be for example-single- or multi-skin roofs, whereby the load-bearing structure (lower skin) as well as the actual roof covering (upper skin) or both consist of structural elements;-single- or multi-skin walls whereby the load-bearing structure (inner skin) as well as the actual cladding (outer skin) or both consist of structural elements; or-suspended ceilings for interior fitting.

Committee
CEN/TC 135
DevelopmentNote
Supersedes PREN 1090-5. (03/2017)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

Standards Relationship
PN EN 1090-5 : 2017 Identical
NS EN 1090-5 : 2017 Identical
BS EN 1090-5:2017 Identical
NEN EN 1090-5 : 2017 Identical
I.S. EN 1090-5:2017 Identical
DIN EN 1090-5:2020-06 Identical
DIN EN 1090-5:2017-07 Identical
UNE-EN 1090-5:2017 Identical

Sorry this product is not available in your region.