EN 14620-4:2006
Withdrawn
Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C - Part 4: Insulation components
13-09-2006
30-11-2006
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Design requirements, performance characteristics, testing
and selection of insulating materials
4.1 General
4.2 Analysis of design requirements
4.3 Assessment of the performance characteristics
4.4 Testing of materials and systems
5 Protection of insulation - water vapour barrier
5.1 General
5.2 Protective structure formed by the outer tank
5.3 Protective cover for external insulation
6 Design of insulation system
6.1 General
6.2 Thermal design
6.3 Structural design
6.4 Insulation for each tank component
6.5 Design for different types of containment
7 Installation
7.1 Introduction
7.2 General requirements
7.3 Inspection and testing
Annex A (informative) Insulation materials
Annex B (normative) Test methods
Annex C (normative) Tank bottom insulation - Limit state theory
Bibliography
This European Standard specifies the requirements for materials, design and installation of the insulation of refrigerated liquefied gas (RLG) storage tanks.RLG storage tanks store liquefied gas with a low boiling point, i.e. below normal ambient temperature.The concept of storing such products in liquid form and in non-pressurized tanks therefore depends on the combination of latent heat of vaporization and thermal insulation.Consequently thermal insulation for RLG storage tanks is not an ancillary part of the containment system (as for most ambient atmospheric hydrocarbon tanks) but it is an essential component and the storage tank cannot operate without a properly designed, installed and maintained insulation system.The main functions of the insulation in RLG storage tanks are:¾to maintain the boil off below the specific limits;¾to protect the non low temperature parts/materials of the tank (mainly the outer tank) by maintaining these parts at their required ambient temperature;¾to limit the cool-down of the foundations/soil underneath the tank to prevent damage by frost heave;¾to prevent/minimize condensation and icing on the outer surfaces of the tank.A wide range of insulation materials is available. However the material properties differ greatly amongst the various generically different materials and also within the same generic group of materials.Therefore within the scope of this European Standard, only general guidance on selection of materials is given.NOTEFor general guidance on selection of materials see Annex A.This European Standard deals with the design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and –165 °C.
| Committee |
CEN/TC 265
|
| DevelopmentNote |
Supersedes PREN 14620-4. (12/2007)
|
| DocumentType |
Standard
|
| PublisherName |
Comite Europeen de Normalisation
|
| Status |
Withdrawn
|
| Standards | Relationship |
| NF EN 14620-4 : 2006 | Identical |
| NEN EN 14620-4 : 2006 | Identical |
| DIN EN 14620-4:2006-12 | Identical |
| I.S. EN 14620-4:2006 | Identical |
| BS EN 14620-4:2006 | Identical |
| PN EN 14620-4 : 2010 | Identical |
| NBN EN 14620-4 : 2007 | Identical |
| NS EN 14620-4 : 1ED 2007 | Identical |
| UNE-EN 14620-4:2008 | Identical |