EN 15026:2007
Withdrawn
Hygrothermal performance of building components and building elements - Assessment of moisture transfer by numerical simulation
11-04-2007
31-10-2007
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, symbols and units
3.1 Terms and definitions
3.2 Symbols and units
4 Hygrothermal equations and material properties
4.1 Assumptions
4.2 Transport of heat and moisture
4.3 Material properties
5 Boundary conditions
5.1 Internal conditions
5.2 External conditions
6 Documentation of input data and results
6.1 General
6.2 Problem description
6.3 Hygrothermal model and numerical solution
6.4 Calculation report
Annex A (normative) Benchmark example - Moisture uptake in
a semi-infinite region
A.1 General
A.2 Problem description
A.3 Results
Annex B (informative) Design of Moisture Reference Years
Annex C (informative) Internal boundary conditions
Bibliography
This standard specifies the equations to be used in a simulation method for calculating the non steady transfer of heat and moisture through building structures. It also provides a benchmark example intended to be used for validating a simulation method claiming conformity with this standard, together with the allowed tolerances.The equations in this standard take account of the following storage and one-dimensional transport phenomena:-heat storage in dry building materials and absorbed water;-heat transport by moisture-dependent thermal conduction;-latent heat transfer by vapour diffusion;-moisture storage by vapour sorption and capillary forces;-moisture transport by vapour diffusion; -moisture transport by liquid transport (surface diffusion and capillary flow).The equations described in this standard account for the following climatic variables:-internal and external temperature;-internal and external humidity;-solar and longwave radiation;-precipitation (normal and driving rain);-wind speed and direction.The hygrothermal equations described in this standard shall not be applied in cases where:-convection takes place through holes and cracks;-two-dimensional effects play an important part (e.g. rising damp, conditions around thermal bridges, effect of gravitational forces);•hydraulic, osmotic, electrophoretic forces are present;daily mean temperatures in the component exceed 50 °C.
| Committee |
CEN/TC 89
|
| DocumentType |
Standard
|
| PublisherName |
Comite Europeen de Normalisation
|
| Status |
Withdrawn
|
| Standards | Relationship |
| DS EN 15026 : 2007 | Identical |
| I.S. EN 15026:2007 | Identical |
| PN EN 15026 : 2008 | Identical |
| BS EN 15026:2007 | Identical |
| NBN EN 15026 : 2007 | Identical |
| NS EN 15026 : 1ED 2007 | Identical |
| NF EN 15026 : 2008 | Identical |
| NEN EN 15026 : 2007 | Identical |
| DIN EN 15026:2007-07 | Identical |
| UNE-EN 15026:2007 | Identical |