• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 15911:2010

Current

Current

The latest, up-to-date edition.

Foodstuffs - Simultaneous determination of nine sweeteners by high performance liquid chromatography and evaporative light scattering detection

Published date

20-10-2010

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Principle
4 Reagents
5 Apparatus and equipment
6 Procedure
7 Calculation of results
8 Precision
9 Test report
Annex A (informative) - Table A.1 - Suitable method conditions
Annex B (informative) - Examples of chromatograms
Annex C (informative) - Precision data
Annex D (informative) - Present EU limits for the nine sweeteners
Bibliography

This European Standard specifies a method for the simultaneous determination of nine sweeteners in beverages and canned or bottled fruits by high performance liquid chromatography (HPLC) with evaporative light scattering detection (HPLC-ELSD). This method has been validated in an interlaboratory study via the analysis of spiked samples on the following matrices:-acesulfame-K (ACS-K) (from 38,3 mg/l to 383,5 mg/l) in beverages and (from 38,4 mg/kg to 391,3 mg/kg) in canned fruits;-alitame (ALI) (from 31,1 mg/l to 114,5 mg/l) in beverages and (from 36 mg/kg to 175,2 mg/kg) in canned fruits;-aspartame (ASP) (from 38,1 mg/l to 702 mg/l) in beverages and (from 37,2 mg/kg to 1 120,2 mg/kg) in canned fruits;-cyclamic acid (CYC) (from 28,3 mg/l to 307,2 mg/l) in beverages and (from 27,5 mg/kg to 1 100,6 mg/kg) in canned fruits;-dulcin (DUL) (from 55,0 mg/l to 115,1 mg/l) in beverages and (from 49,8 mg/kg to 172,6 mg/kg) in canned fruits;-neotame (NEO) (from 37,6 mg/l to 115,3 mg/l) in beverages and (from 37,3 mg/kg to 173,7 mg/kg) in canned fruits;-neohesperidine dihydrochalcone (NHDC) (from 31,4 mg/l to 59,3 mg/l) in beverages and (from 35,3 mg/kg to 59,3 mg/kg) in canned fruits;-saccharin (SAC) (from 36,2 mg/l to 87,6 mg/l) in beverages and (from 44,3 mg/kg to 235,3 mg/kg) in canned fruits;-sucralose (SCL) (from 36,8 mg/l to 346,8 mg/l) in beverages and (from 35,3 mg/kg to 462,4 mg/kg) in canned fruits.For further information on the validation results see Annex C.NOTEThe method has been fully validated [1] through collaborative trial, according to the IUPAC Harmonised Protocol [2], on analyte-matrix combinations of all nine sweeteners in beverages and canned or bottled fruits.

Committee
CEN/TC 275
DevelopmentNote
Supersedes PREN 15911. (04/2011)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

Standards Relationship
DIN EN 15911:2011-01 Identical
NS EN 15911 : 2010 Identical
PN EN 15911 : 2010 Identical
NF EN 15911 : 2010 Identical
I.S. EN 15911:2010 Identical
BS EN 15911:2010 Identical
NBN EN 15911 : 2010 Identical
NEN EN 15911 : 2010 Identical
UNE-EN 15911:2011 Identical

ISO 3696:1987 Water for analytical laboratory use — Specification and test methods
EN ISO 3696:1995 Water for analytical laboratory use - Specification and test methods (ISO 3696:1987)

Sorry this product is not available in your region.