EN 3774-004:2014
Withdrawn
Aerospace series - Circuit breakers, three-pole, temperature compensated, rated currents 1 A to 25 A - Part 004: UNC thread terminals - Product standard
30-07-2014
31-01-2015
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Dimensions and mass
5 Characteristics
6 Designation
7 Rated current code
8 Delivery codes
9 Marking
10 Technical specification
This European Standard specifies the characteristics of three-pole circuit breakers, temperature compensated with a rated current from 1 A to 25 A, used in aircraft on-board circuits at a temperature between − 55 °C and 125 °C for ratings ≤ 15 A and − 55 °C to 90 °C for ratings > 15 A and at an altitude of 22 000 m max.These circuit breakers are operated by a push-pull type single pushbutton (actuator), with delayed action 'trip-free' tripping.They will continue to function up to the short-circuit current.