EN ISO 7199:2017

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Cardiovascular implants and artificial organs - Blood-gas exchangers (oxygenators) (ISO 7199:2016)

Published date

25-01-2017

Superseded date

09-04-2020

Sorry this product is not available in your region.

European foreword
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Tests and measurements to determine compliance
  with this document
6 Information supplied by the manufacturer
7 Packaging
Bibliography
Annex ZA (informative) - Relationship between this
         European standard and the essential requirements
         of Directive 93/42/EEC [OJ L 169] aimed to be covered

ISO 7199:2016 specifies requirements for sterile, single-use, extracorporeal blood-gas exchangers (oxygenators) intended for supply of oxygen to, and removal of carbon dioxide from, the blood of humans.ISO 7199:2016 also applies to heat exchangers and arterial filters that are integral parts of the oxygenator.ISO 7199:2016 also applies to external equipment unique to the use of the oxygenator.ISO 7199:2016 does not apply to- implanted oxygenators,- liquid oxygenators,- extracorporeal circuits (blood tubing),- separate heat exchangers,- separate ancillary devices, and- separate arterial line filter.

Committee
CEN/TC 205
DevelopmentNote
Supersedes EN 12022. (09/2014)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
Supersedes

ISO 11137-1:2006 Sterilization of health care products — Radiation — Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
ISO 10993-4:2017 Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood
ISO 11607-2:2006 Packaging for terminally sterilized medical devices — Part 2: Validation requirements for forming, sealing and assembly processes
ISO 11135:2014 Sterilization of health-care products — Ethylene oxide — Requirements for the development, validation and routine control of a sterilization process for medical devices
EN ISO 10993-11:2009 Biological evaluation of medical devices - Part 11: Tests for systemic toxicity (ISO 10993-11:2006)
ISO 8637:2010 Cardiovascular implants and extracorporeal systems — Haemodialysers, haemodiafilters, haemofilters and haemoconcentrators
ISO 13485:2016 Medical devices — Quality management systems — Requirements for regulatory purposes
ISO/TS 23810:2012 Cardiovascular implants and artificial organs — Checklist for preoperative extracorporeal circulation equipment setup
EN ISO 10993-7 : 2008 COR 2009 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS (ISO 10993-7:2008/COR 1:2009)
EN ISO 10993-4:2017 Biological evaluation of medical devices - Part 4: Selection of tests for interactions with blood (ISO 10993-4:2017)
ISO 15675:2016 Cardiovascular implants and artificial organs — Cardiopulmonary bypass systems — Arterial blood line filters
EN ISO 11135:2014 Sterilization of health-care products - Ethylene oxide - Requirements for the development, validation and routine control of a sterilization process for medical devices (ISO 11135:2014)
ISO 10993-11:2017 Biological evaluation of medical devices — Part 11: Tests for systemic toxicity
ISO 10993-7:2008 Biological evaluation of medical devices — Part 7: Ethylene oxide sterilization residuals
ISO 10993-1:2009 Biological evaluation of medical devices — Part 1: Evaluation and testing within a risk management process
EN ISO 11137-1:2015 Sterilization of health care products - Radiation - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices (ISO 11137-1:2006, including Amd 1:2013)
EN ISO 17665-1:2006 Sterilization of health care products - Moist heat - Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices (ISO 17665-1:2006)
ISO 14971:2007 Medical devices — Application of risk management to medical devices
ISO 11607-1:2006 Packaging for terminally sterilized medical devices — Part 1: Requirements for materials, sterile barrier systems and packaging systems
ISO 594-2:1998 Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment — Part 2: Lock fittings
ISO 17665-1:2006 Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices