ENV 13381-7:2002

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Test methods for determining the contribution to the fire resistance of structural members - Part 7: Applied protection to timber members

Published date

10-07-2002

Withdrawn date

07-03-2023

Superseded by

EN 13381-7:2019

Sorry this product is not available in your region.
Summarise this standard

Foreword
1 Scope
2 Normative references
3 Terms and definitions, symbols and units
4 Test equipment
5 Test conditions
6 Test specimens
7 Installation of the test construction
8 Conditioning of the test construction
9 Application of instrumentation
10 Test procedure
11 Test results
12 Test report
13 Assessment
14 Report of the assessment
15 Limits of applicability of the results of the
    assessment
Annex A (normative) Test method to the smouldering fire
        or slow heating curve
Annex B (informative) Guidelines for fire protection of
        timber structures according to ENV 1995-1-2 -
        Loadbearing function
Annex C (normative) Measurement of properties of fire
        protection materials
Annex D (informative) Alternative construction for loaded
        beam test specimen
Bibliography

This Part of this European Prestandard specifies a test method to be followed for determining the contribution of fire protection systems to the fire resistance of structural timber members. Such fire protection systems include claddings, sprayed fire protection and coatings.The method is applicable to all fire protection systems used for the protection of timber members. These can be fixed directly, totally or in part, to the timber member and can include an air gap between the fire protection system and the timber member, as an integral part of its design. Evaluation of timber constructions protected by horizontal or vertical protective membranes are the subject of prENV 13381-1 or prENV 13381-2 respectively.The test method is applicable to the determination of the contribution of fire protection systems to the fire resistance of loadbearing timber structural members and non-loadbearing parts of the works, including floors, roofs, walls, beams and columns. It is also applicable to timber structural members incorporating insulating materials between the timber members, e.g. between timber joists in floor constructions. The test method and its assessment procedure is designed to permit direct application of the results to cover a range of thicknesses of the applied fire protection material. This European Prestandard contains the fire test which specifies the test to be carried out to determine the ability of the fire protection system to delay the temperature rise throughout the timber member, to determine the ability of the fire protection system to remain coherent and fixed to the timber member and to provide data of the temperature profile throughout the timber test member, when exposed to the standard temperature/time curve according to the procedures defined herein.In special circumstances, where specified in national building regulations, there can be a need to subject reactive protection material to a smouldering curve. The test

Committee
CEN/TC 127
DocumentType
Standard Recommendation
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn
SupersededBy

Sorry this product is not available in your region.