• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

I.S. HD 22-1:2002

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 1: GENERAL REQUIREMENTS

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2002

Superseded date

18-05-2011

Superseded by

I.S. EN 50525-1:2011

£56.37
Excluding VAT

1 General
  1.1 Scope
  1.2 Object
  1.3 Common marking
2 Definitions
  2.1 Definitions relating to insulating and sheathing
      materials and their processing
  2.2 Definitions relating to the tests
  2.3 Rated voltage
3 Marking
  3.1 Indication of origin
  3.2 Continuity of marks
  3.3 Durability
  3.4 Legibility
  3.5 Common marking
  3.6 Use of the name CENELEC
  3.7 Code designation
4 Core identification
  4.1 General requirements
  4.2 Colour schemes
  4.3 Colour combination green-and-yellow
  4.4 Core identification of flexible cables by the
      'Marking by inscription' method
5 General requirements for the construction of cables
  5.1 Conductors
  5.2 Insulation
  5.3 Filler
  5.4 Textile braid
  5.5 Sheath
  5.6 Tests on completed cables
6 Guide to use of the cables
Annex A (normative) Normative references
Annex B (informative) National marking

Provides rigid and flexible cables, sheathed and unsheathed, and insulated with cross-linked material, of rated voltages U[0]/U up to and including 450/750 V used in power installations.

DocumentType
Standard
Pages
66
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

Standards Relationship
HD 22-1 : 200S4 Identical

EN 50268-1:1999 Common test methods for cables under fire conditions - Measurement of smoke density of cables burning under defined conditions - Part 1: Apparatus
EN 50266-2-1 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-1: PROCEDURES - CATEGORY A F/R
EN 50266-2-4 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-4: PROCEDURES - CATEGORY C
EN 50267-2-1:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas
EN 60811-3-2 : 95 AMD 2 2004 INSULATING AND SHEATHING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 3-2: METHODS SPECIFIC TO PVC COMPOUNDS - LOSS OF MASS TEST - THERMAL STABILITY TEST
EN 60811-1-3:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-3: GENERAL APPLICATION - METHODS FOR DETERMINING THE DENSITY - WATER ABSORPTION TESTS - SHRINKAGE TEST
EN 60811-4-2:2004 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-2: Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature - Wrapping test after conditioning at elevated temperature - Wrapping test after thermal ageing in air - Measurement of mass increase - Long-term stability test - Test method for copper-catalyzed oxidative degradation
EN 50266-2-2 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-2: PROCEDURES - CATEGORY A
EN 50266-1:2001 Common test methods for cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables - Part 1: Apparatus
EN 60811-3-1 : 95 AMD 2 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - METHODS SPECIFIC TO PVC COMPOUNDS - PRESSURE TEST AT HIGH TEMPERATURE - TESTS FOR RESISTANCE TO CRACKING
EN 50267-1:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 1: Apparatus
EN 60811-5-1:1999/A1:2004 INSULATING AND SHEATHING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 5-1: METHODS SPECIFIC TO FILLING COMPOUNDS - DROP POINT - SEPARATION OF OIL - LOWER TEMPERATURE BRITTLENESS - TOTAL ACID NUMBER - ABSENCE OF CORROSIVE COMPONENTS - PERMITTIVITY AT 23 DEGREE C - D.C. RESISTIVITY AT 23 DEGREE C AND 100 DEGREE C
HD 308 S2:2001 Identification of cores in cables and flexible cords
HD 383 : S2 AMD 2 CONDUCTORS OF INSULATED CABLES - GUIDE TO THE DIMENSIONAL LIMITS OF CIRCULAR CONDUCTORS
EN 50266-2-3 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-3: PROCEDURES - CATEGORY B
EN 50268-2:1999 Common test methods for cables under fire conditions - Measurement of smoke density of cables burning under defined conditions - Part 2: Procedure
EN 50265-2-2:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-2: Procedures - Diffusion flame
EN 60811-4-1:2004 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-1: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - Measurement of the melt flow index - Carbon black and/or mineral filler content measurement in polyethylene by direct combustion - Measurement of carbon black content by thermogravimetric analysis (TGA) - Assessment of carbon black dispersion in polyethylene using a microscope
EN 60811-1-2:1995/A2:2000 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS
HD 516 S2:1997/A2:2008 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES
HD 402 : 200S2 STANDARD COLOURS FOR INSULATION FOR LOW-FREQUENCY CABLES AND WIRES
EN 50267-2-3:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-3: Procedures - Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity
EN 60811-2-1 : 98 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 2-1: METHODS SPECIFIC TO ELASTOMERIC COMPOUNDS - OZONE RESISTANCE, HOT SET AND MINERAL OIL IMMERSION TESTS
HD 361 : S3 AMD 1 2006 SYSTEM FOR CABLE DESIGNATION
EN 50334:2001 Marking by inscription for the identification of cores of electric cables
EN 50266-2-5 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-5: PROCEDURES - SMALL CABLES - CATEGORY D
EN 50267-2-2:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity
EN 50265-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 1: Apparatus
EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
EN 50265-2-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-1: Procedures - 1 kW pre-mixed flame
EN 60811-1-4:1995/A2:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE

£56.37
Excluding VAT