IEC 60079-14:2024

Current

Current

The latest, up-to-date edition.

Explosive atmospheres - Part 14: Electrical installation design, selection and installation of equipment, including initial inspection

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

30-08-2024

£389.43
Excluding VAT
Summarise this standard

IEC 60079:2024 contains the specific requirements for the design of electrical systems, selection, installation and the required initial inspection of electrical installations of Ex Equipment in, or associated with, explosive atmospheres including requirements for documentation and personnel competency.
These requirements are in addition to the requirements for installations in non-hazardous areas.
This document applies to all electrical Ex Equipment including fixed, transportable, portable and personal, and installations, permanent or temporary.
This document does not apply to:
• electrical installations in mines susceptible to firedamp;
• inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing);
• rooms used for medical purposes;
• electrical installations in areas where the hazard is due to flammable mist; and
• installation of non-electrical Ex Equipment (unless being part of an equipment assembly according IEC TS 60079-46).
No account is taken in this document of the toxic hazards that are associated with flammable gases, liquids and dusts in concentrations that are usually very much less than the lower flammable limit. In locations where personnel could be exposed to potentially toxic concentrations of flammable material, appropriate precautions are necessary. Such precautions are outside the scope of this document.
This sixth edition cancels and replaces the fifth edition published in 2013. This edition constitutes a technical revision. Edition 6 is a major restructure and introduces a number of technical changes from the previous edition (2013), see Table 1 of the foreword for detailed information.

Committee
TC 31/SC 31J
DocumentType
Standard
Pages
300
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

Frequently Asked Questions

IEC 60079-14 applies to oil and gas, chemical, mining and other sites where flammable gas, vapour or dust may create explosive atmospheres. It is an international standard published by International Electrotechnical Commission (IEC).

IEC 60079-14 is International Electrotechnical Commission (IEC)'s standard for explosive atmospheres, while API 505 covers hazardous location classification (United States). IEC 60079-14 covers equipment, area classification, installation, inspection or protection methods for electrical systems in explosive atmospheres. API 505 provides methods for classifying petroleum facility locations where flammable gases or vapours may be present.

IEC 60079-14 is an international standard published by International Electrotechnical Commission (IEC), and is applied internationally rather than in a single country.

IEC 60079-14 covers equipment, area classification, installation, inspection or protection methods for electrical systems in explosive atmospheres. It applies to oil and gas, chemical, mining and other sites where flammable gas, vapour or dust may create explosive atmospheres.

IEC 60079-14 covers equipment, area classification, installation, inspection or protection methods for electrical systems in explosive atmospheres. It is an international standard published by International Electrotechnical Commission (IEC).