FOREWORD
1 General
2 Terms and definitions
3 Classification
4 Characteristics of circuit-breakers
5 Product information
6 Normal service, mounting and transport conditions
7 Constructional and performance requirements
8 Tests
Annex A (normative) - Co-ordination between a circuit-breaker
        and another short-circuit protective device associated
        in the same circuit
Annex B (normative) - Circuit-breakers incorporating residual
        current protection
Annex C (normative) - Individual pole short-circuit test sequence
Annex D Vacant
Annex E (informative) - Items subject to agreement between
        manufacturer and user
Annex F (normative) - Additional tests for circuit-breakers
        with electronic over-current protection
Annex H (normative) - Test sequence for circuit-breakers for
        IT systems
Annex J (normative) - Electromagnetic compatibility (EMC)
        - Requirements and test methods for circuit-breakers
Annex K (informative) - Glossary of symbols and graphical
        representation of characteristics
Annex L (normative) - Circuit-breakers not fulfilling the
        requirements for overcurrent protection
Annex M (normative) - Modular residual current devices
        (without integral current breaking device)
Annex N (normative) - Electromagnetic compatibility (EMC)
        - Additional requirements and test methods for devices
        not covered by Annex B, Annex F and Annex M
Annex O (normative) - Instantaneous trip circuit-breakers
        (ICB)
Annex P (normative) - DC circuit-breakers for use in
        photovoltaic (PV) applications
Annex Q Vacant
Annex R (normative) - Circuit-breakers incorporating
        residual current protection with automatic re-closing
        functions
Bibliography

IEC 60947-2:2016 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60947-2:2016 applies to circuit-breakers, the main contacts of which are intended to be connected to circuits, the rated voltage of
which does not exceed 1 000 V a.c. or 1 500 V d.c.; it also contains additional requirements for integrally fused circuit-breakers. This fifth edition cancels and replaces the fourth edition published in 2006, Amendment 1:2009 and Amendment 2:2013. This edition constitutes a technical revision. This edition includes the following significant additions with respect to the previous edition:
- tests for verification of selectivity in Annex A (see A.5.3);
- critical load current tests for d.c. circuit-breakers (see 8.3.9);
- new Annex P for circuit-breakers for use in photovoltaic applications;
- new Annex R for residual-current circuit-breakers with automatic reclosing functions.
The contents of the corrigendum of November 2016 have been included in this copy.

Committee
TC 121/SC 121A
DevelopmentNote
To be read in conjunction with IEC 60947-1. Stability date: 2018. (06/2016)
DocumentType
Redline
Pages
751
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
IEC 60364-7-712:2017 Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems
IEC 62475:2010 High-current test techniques - Definitions and requirements for test currents and measuring systems
IEC 60947-4-1:2009+AMD1:2012 CSV Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
IEC 61131-1:2003 Programmable controllers - Part 1: General information
IEC 60934:2000+AMD1:2007+AMD2:2013 CSV Circuit-breakers for equipment (CBE)
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
IEC 60050-442:1998 International Electrotechnical Vocabulary (IEV) - Part 442: Electrical accessories
IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
IEC 60410:1973 Sampling plans and procedures for inspection by attributes
IEC TR 60755:2008 General requirements for residual current operated protective devices
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units
EN 50557:2011 Requirements for automatic reclosing devices (ARDs) for circuit breakers-RCBOs-RCCBs for household and similar uses
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC TR 60664-2-1:2011 Insulation coordination for equipment within low-voltage systems - Part 2-1: Application guide - Explanation of the application of the IEC 60664 series, dimensioning examples and dielectric testing
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

£731.77
Excluding VAT