• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV

Superseded

Superseded

View Superseded by

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

12-09-2013

Superseded date

21-11-2024

Superseded by

IEC 61008-1:2024

£1,240.75
Excluding VAT
Summarise this standard

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Classification
5 Characteristics of RCCBs
6 Marking and other product information
7 Standard conditions for operation in service and
  for installation
8 Requirements for construction and operation
9 Tests
Annex A (normative) - Test sequence and number of
        samples to be submitted for certification
        purposes
Annex B (normative) - Determination of clearances and
        creepage distances
Annex C (normative) - Arrangement for the detection of
        the emission of ionized gases during short-circuit
        tests
Annex D (normative) - Routine tests
Annex E (informative) - Void
Annex IA (informative) - Methods for determination of
         short-circuit power-factor
Annex IB (informative) - Glossary of symbols
Annex IC (informative) - Examples of terminal designs
Annex ID (informative) - Correspondence between ISO
         and AWG copper conductors
Annex IE (informative) - Follow-up testing program for
         RCCBs
Annex IF (informative) - SCPDs for short-circuit tests
Annex J (normative) - Particular requirements for
        RCCBs with screwless type terminals
        for external copper conductors
Annex K (normative) - Particular requirements
        for RCCBs with flat quick-connect
        terminations
Annex L (normative) - Specific requirements
        for RCCBs with screw-type terminals
        for external untreated aluminium
        conductors and with aluminium
        screw-type terminals for use with
        copper or with aluminium conductors
Bibliography

IEC 61008-1:2010+A1:2012+A2:2013 applies to residual current operated circuit-breakers functionally independent of, or functionally dependent on, line voltage, for household and similar uses, not incorporating overcurrent protection (hereafter referred to as RCCBs), for rated voltages not exceeding 440 V a.c. with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A, intended principally for protection against shock hazard. This third edition cancels and replaces the second edition published in 1996, amendment 1 (2002) and amendment 2 (2006). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- complete revision of EMC sequences, including the new test T.2.6 already approved in IEC 61543;
- clarification of RCDs current/time characteristics reported in Tables 1 and 2;
- revision of test procedure for IΔn between 5 A and 200 A;
- testing procedure regarding the 6mA d.c. current superimposed to the fault current;
- improvement highlighting RCDs with multiple sensitivity;
- tests for the use of RCCBs in IT systems.
This consolidated version consists of the third edition (2010), its amendment 1 (2012), its amendment 2 (2013) and the corrigendum of January 2014. Therefore, no need to order amendments in addition to this publication.

Committee
TC 23/SC 23E
DevelopmentNote
Also available in CD-ROM format. (09/2013) Stability date: 2018. (11/2017)
DocumentType
Standard
Pages
680
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

⚠

A newer version of this standard is available.

View Current Edition
£1,240.75
Excluding VAT