IEC 61266:1994

Current

Current

The latest, up-to-date edition.

Ultrasonics - Hand-held probe Doppler foetal heartbeat detectors - Performance requirements and methods of measurement and reporting

Available format(s)

Hardcopy , PDF

Language(s)

English - French, Spanish, Castilian

Published date

15-12-1994

£190.19
Excluding VAT

FOREWORD
INTRODUCTION
Clause
1 Scope
2 Normative references
3 Definitions
4 List of symbols
5 Configuration
6 Performance
   6.1 Acoustic working frequency
7 Safety
8 Tests
   8.1 Acoustic working frequency
   8.2 Output power
   8.3 Spatial-peak temporal-peak acoustic pressure
   8.4 Effective area of the ultrasonic transducer
        active element
   8.5 Overall sensitivity
9 Preferred method for reporting performance of
   existing equipment
10 Specifications for labelling
11 Sampling
Figures
Annexes
A Choice of target and determination of target
   plane-wave reflection loss
B Typical test equipment and test procedures
C Determination of the two-way insertion loss of
   acoustic attenuators
D Rationale
E Bibliography

Is applicable to ultrasonic Doppler foetal heartbeat detectors which generate a single ultrasound beam and consist of a hand-held probe which is applied to the maternal abdomen to obtain information on foetal heart activity by means of the Doppler method using continuous wave (c.w) or quasi-continuous wave ultrasound.Establishes - methods of measurement of performances - requirements for the performance and the - reporting of performance

DevelopmentNote
Also numbered as BS EN 61266. (09/2005) Stability Date: 2020. (09/2017)
DocumentType
Standard
Pages
60
PublisherName
International Electrotechnical Committee
Status
Current

Standards Relationship
NF EN 61266 : 1996 Identical
NEN 11266 : 1995 Identical
I.S. EN 61266:1997 Identical
PN EN 61266 : 2002 Identical
AS/NZS 4374:1996 Identical
CEI EN 61266 : 1998 Identical
EN 61266:1995 Corresponds
DIN EN 61266:1996-06 Identical
EN 61266:1995 Identical
UNE-EN 61266:1996 Identical

VDE 0418-3-31:1999-04 ELECTRICITY METERING EQUIPMENT (A.C.) - PARTICULAR REQUIREMENTS - PART 31: PULSE OUTPUT DEVICES FOR ELECTROMECHANICAL AND ELECTRONIC METERS (TWO WIRES ONLY)
DIN EN 62053-31:1999-04 ELECTRICITY METERING EQUIPMENT (A.C.) - PARTICULAR REQUIREMENTS - PART 31: PULSE OUTPUT DEVICES FOR ELECTROMECHANICAL AND ELECTRONIC METERS (TWO WIRES ONLY)
99/200863 DC : DRAFT JAN 1999 IEC 61895. TS. ED. 1 - ULTRASONICS - PULSED DOPPLER DIAGNOSTIC SYSTEMS - TEST PROCEDURES TO DETERMINE PERFORMANCE

IEC 61161:2013 Ultrasonics - Power measurement - Radiation force balances and performance requirements
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC TR 60854:1986 Methods of measuring the performance of ultrasonic pulse-echo diagnostic equipment
IEC 61101:1991 The absolute calibration of hydrophones using the planar scanning technique in the frequency range 0.5 MHz to 15 MHz
IEC 61157:2007+AMD1:2013 CSV Standard means for the reporting of the acoustic output of medicaldiagnostic ultrasonic equipment
IEC 60866:1987 Characteristics and calibration of hydrophones for operation in the frequency range 0.5 MHz to 15 MHz

£190.19
Excluding VAT