IEC 61267:2005
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
Hardcopy , PDF
English - French
09-11-2005
09-12-2025
FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 Common aspects - Adjustment procedures
5 RQR - RADIATION QUALITIES in RADIATION BEAMS emerging
from the X-RAY SOURCE
6 RQA - RADIATION QUALITIES based on a PHANTOM made up
of an aluminium ADDED FILTER
7 RQC - RADIATION QUALITIES based on copper ADDED FILTER
8 RQT - RADIATION QUALITIES based on copper ADDED FILTER
9 Standard RADIATION CONDITIONS RQN
10 Standard RADIATION CONDITIONS RQB
11 Standard RADIATION CONDITION RQR-M
12 Standard RADIATION CONDITION RQA-M
13 Standard RADIATION CONDITIONS RQN-M
14 Standard RADIATION CONDITION RQB-M
Annex A (informative) Rationale
Annex B (informative) Determination of the amount of
additional filtration
Annex C (normative) Measurement of the PRACTICAL PEAK
VOLTAGE
Annex D (informative) Overview of radiation qualities and
radiation conditions
Bibliography
Index of defined terms
This International Standard applies to test procedures which, for the determination of characteristics of systems or components of medical diagnostic X-ray equipment, require well-defined radiation conditions.Except for mammography, this standard does not apply to conditions where discontinuities in radiation absorption of elements are deliberately used to modify properties of the radiation beam (for example by rare earth filters).This standard deals with methods for generating radiation beams with radiation conditions which can be used under test conditions typically found in test laboratories or in manufacturing facilities for the determination of characteristics of medical diagnostic X-ray equipment. Examples of such radiation qualities are radiation beams emerging through the filtration from the X-ray source assembly. radiation conditions represent the more general case, where scattered radiation emerges from an exit surface of a patient or a phantom. This requires a well defined geometrical arrangement.
| Committee |
TC 62/SC 62C
|
| DocumentType |
Standard
|
| Pages |
85
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| AS/NZS IEC 61267:2022 | Identical |
| NEN EN IEC 61267 : 2006 | Identical |
| PN EN 61267 : 2006 | Identical |
| BS EN 61267:2006 | Identical |
| EN 61267:2006 | Identical |
| JIS T 61267:2014 | Identical |
| BS EN 60738-1-4:2008 | Identical |
| CEI EN 61267 : 2006 | Identical |
| NEN 11267 : 1995 | Identical |
| I.S. EN 61267:2006 | Identical |
| UNE-EN 61267:2006 | Identical |
| GOST R IEC 61267 : 2001 | Identical |
| I.S. EN 50078:1995 | Identical |
| DIN EN 61267:2009-01 | Identical |