IEC 61347-2-8:2000+AMD1:2006 CSV
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps
Hardcopy , PDF
English - French
14-03-2006
14-05-2024
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General requirements
4.1 Capacitors and other components
4.2 Thermally protected ballasts
5 General notes on tests
6 Classification
7 Marking
7.1 Mandatory markings
7.2 Information to be provided, if applicable
7.3 Other information
8 Protection against accidental contact with live
parts
9 Terminals
10 Provisions for earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings
14 Ballast heating
14.1 Pre-test, checks and measures
14.2 Voltage across capacitors
14.3 Ballast heating test
15 High-voltage impulse testing
16 Fault conditions
17 Construction
18 Creepage distances and clearances
19 Screws, current-carrying parts and connections
20 Resistance to heat, fire and tracking
21 Resistance to corrosion
22 No-load output voltage
Annexes
Annex A (normative) Test to establish whether a conductive
part is a live part which may cause an
electric shock
Annex B (normative) Particular requirements for thermally
protected lamp controlgear
Annex C (normative) Particular requirements for electronic
lamp controlgear with means of protection
against overheating
Annex D (normative) Requirements for carrying out the heating
tests of thermally protected lamp controlgear
Annex E (normative) Use of constant S other than 4 500 in
t[w] tests
Annex F (normative) Draught-proof enclosure
Annex G (normative) Explanation of the derivation of the values
of pulse voltages
Annex H (normative) Tests
Annex I (normative) Method for selection of varistors
Annex J (informative) Explanation of ballast temperatures
Annex K (normative) Additional requirements for
built-in magnetic ballasts with
double or reinforced insulation
Bibliography
This part of IEC 61347 specifies safety requirements for ballasts, excluding resistance types, for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with fluorescent lamps with or without pre-heated cathodes operated with or without a starter or starting device and having rated wattages, dimensions and characteristics as specified in IEC 60081 and 60901. This consolidated version consists of the first edition (2000) and its amendment 1 (2006). Therefore, no need to order amendment in addition to this publication. The contents of the corrigendum of August 2012 have been included in this copy.
| Committee |
TC 34/SC 34C
|
| DevelopmentNote |
Supersedes IEC 60920 (01/2001) Stability Date: 2017. (09/2017)
|
| DocumentType |
Standard
|
| Pages |
43
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| GOST R IEC 61347-2-8 : 2011 | Identical |
| NEN EN IEC 61347-2-8 : 2001 AMD 1 2006 | Identical |
| PN EN 61347-2-8 : 2003 AC 2011 | Identical |
| AS/NZS 61347.2.8:2003 | Identical |
| VDE 0712-38 : 2006 COR 2 2013 | Identical |
| DIN EN 61347-2-8 : 2006 COR 2 2013 | Identical |
| BS EN 61347-2-8 : 2001 | Identical |
| NF EN 61347-2-8 : 2001 AMD 1 2006 | Identical |
| DS EN 61347-2-8 : 2001 COR 2011 | Identical |
| UNE-EN 61347-2-8:2002 | Identical |