IEC 61643-1:2005

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

30-03-2005

Superseded date

09-03-2011

Superseded by

IEC 61643-11:2011

£344.15
Excluding VAT
Summarise this standard

FOREWORD
INTRODUCTION
1 General
  1.1 Scope
  1.2 Normative references
2 Service conditions
  2.1 Normal
  2.2 Abnormal
3 Definitions
4 Classifications
  4.1 Number of ports
  4.2 SPD design topology
  4.3 SPD class I, II and III tests
  4.4 Location
  4.5 Accessibility
  4.6 Mounting method
  4.7 SPD disconnector
  4.8 Overcurrent protection
  4.9 Degree of protection provided by enclosures according
       to IP codes of IEC 60529
  4.10 Temperature range
  4.11 System
  4.12 Multipole SPD
5 Standard ratings
  5.1 Preferred values of impulse current for class I
       tests I[imp]
  5.2 Preferred values of nominal discharge current for
       class II tests I[n]
  5.3 Preferred values of open-circuit voltage for class
       III tests U[oc]
  5.4 Preferred values of voltage protection level U[p]
  5.5 Preferred values of r.m.s. or d.c. maximum continuous
       operating voltage U[c]
6 Requirements
  6.1 General requirements
  6.2 Electrical requirements
  6.3 Mechanical requirements
  6.4 Environmental requirements
  6.5 Safety requirements
  6.6 Additional test requirements for two-port SPDs and
       one-port SPDs with separate input/output terminals
7 Type tests
  7.1 General testing procedures
  7.2 Identification and marking
  7.3 Terminals and connections
  7.4 Testing for protection against direct contact
  7.5 Determination of the measured limiting voltage
  7.6 Operating duty test
  7.7 SPD disconnectors and safety performance of
       overstressed SPDs
  7.8 Test for two-port SPDs and one-port SPDs with separate
       input/output terminals
  7.9 Additional tests
8 Routine and acceptance tests
  8.1 Routine tests
  8.2 Acceptance tests
Annex A (informative) Considerations for SPDs when class I
                      tests are to be applied
Annex B (normative) TOV values
Bibliography

This part of IEC 61643 is applicable to devices for surge protection against indirect and direct effects of lightning or other transient overvoltages. These devices are packaged to be connected to 50/60 Hz a.c. and d.c. power circuits, and equipment rated up to 1 000 V r.m.s. or 1 500 V d.c. Performance characteristics, standard methods for testing, and ratings are established for these devices that contain at least one nonlinear component that is intended to limit surge voltages and divert surge currents.

Committee
TC 37/SC 37A
DocumentType
Standard
Pages
159
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
VDE 0675-6-11 : 2013 Identical
UNE-EN 61643-11:2013 Identical
I.S. EN 61643-11:2012 Identical

⚠

A newer version of this standard is available.

View Current Edition
£344.15