• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 62153-4-10:2015

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Metallic communication cable test methods - Part 4-10: Electromagnetic compatibility (EMC) - Transfer impedance and screening attenuation of feed-throughs and electromagnetic gaskets - Double coaxial test method

Available format(s)

Hardcopy , PDF

Language(s)

English - French, English

Published date

04-11-2015

Superseded date

30-07-2020

£190.19
Excluding VAT

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Principle of the test method
5 Procedure
6 Measurement
7 Expression of results
Annex A (informative) - Background for the measurement
        of the shielding effectiveness of feed-throughs
        and electromagnetic gaskets
Annex B (informative) - Reference device for verification
        measurement
Annex C (informative) - Impact of ground loops on low
        frequency measurements
Bibliography

IEC 62153-4-10:2015 details a coaxial method suitable for determining the transfer impedance and/or screening attenuation of feed-throughs and electromagnetic gaskets. The shielded screening attenuation test set-up according to IEC 62153-4-4 (triaxial method) has been modified to take into account the particularities of feed-throughs and gaskets. This second edition cancels and replaces the first edition published in 2009. It constitutes a technical revision. The main technical changes with regard to the previous edition are as follows:
- addition of a new clause that describes a procedure for verification of the measurement set-up and further information regarding sample preparation;
- addition of a new Annex that describes how to improve measurement certainty in the very low frequency area.

Committee
TC 46
DevelopmentNote
Stability Date: 2018. (11/2015) NEW CHILD AMD 1 2020 IS ADDED
DocumentType
Standard
Pages
72
ProductNote
NEW CHILD AMD 1 2020 IS ADDED
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
BS IEC 62153-4-10:2015 Identical
NEN IEC 62153-4-10 : 2015 Identical
DS IEC 62153-4-10 : 2015 Identical

17/30348794 DC : 0 BS EN 62153-4-7+A1 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE ZT AND SCREENING ATTENUATION AS OR COUPLING ATTENUATION AC OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD
13/30279876 DC : 0 BS EN 62153-4-15 ED.1 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-15: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING TRANSFER IMPEDANCE AND SCREENING ATTENUATION - OR COUPLING ATTENUATION WITH TRIAXIAL CELL
I.S. EN 62153-4-7:2016 METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE Z[T] AND SCREENING ATTENUATION A[S] OR COUPLING ATTENUATION A[C] OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD
IEC 62153-4-15:2015 Metallic communication cable test methods - Part 4-15: Electromagnetic compatibility (EMC) - Test method for measuring transfer impedance and screening attenuation - or coupling attenuation with triaxial cell
EN 62153-4-7:2016/AC:2016-05 METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE Z[T] AND SCREENING ATTENUATION A[S] OR COUPLING ATTENUATION A[C] OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD (IEC 62153-4-7:2015/COR1:2016)
BS IEC 62153-4-15:2015 Metallic Communication Cable test methods Electromagnetic compatibility (EMC). Test method for measuring transfer impedance and screening attenuation or coupling attenuation with triaxial cell
BS EN 62153-4-7 : 2016 METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-7: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING OF TRANSFER IMPEDANCE Z[T] AND SCREENING ATTENUATION A[S] OR COUPLING ATTENUATION A[C] OF CONNECTORS AND ASSEMBLIES UP TO AND ABOVE 3 GHZ - TRIAXIAL TUBE IN TUBE METHOD
IEC TS 62153-4-1:2014 Metallic communication cable test methods - Part 4-1: Electromagnetic compatibility (EMC) - Introduction to electromagnetic screening measurements
IEC 62153-4-7:2015 Metallic communication cable test methods - Part 4-7: Electromagnetic compatibility (EMC) - Test method for measuring of transfer impedance Z<sub>T</sub> and screening attenuation a<sub>S</sub> or coupling attenuation a<sub>C</sub> of connectors and assemblies up to and above 3 GHz - Triaxial tube in tube method

IEC 62153-4-7:2015 Metallic communication cable test methods - Part 4-7: Electromagnetic compatibility (EMC) - Test method for measuring of transfer impedance Z<sub>T</sub> and screening attenuation a<sub>S</sub> or coupling attenuation a<sub>C</sub> of connectors and assemblies up to and above 3 GHz - Triaxial tube in tube method
IEC TR 62152:2009 Transmission properties of cascaded two-ports or quadripols - Background of terms and definitions
IEC 62153-4-4:2015 Metallic communication cable test methods - Part 4-4: Electromagnetic compatibility (EMC) - Test method for measuring of the screening attenuation as up to and above 3 GHz, triaxial method
IEC TS 62153-4-1:2014 Metallic communication cable test methods - Part 4-1: Electromagnetic compatibility (EMC) - Introduction to electromagnetic screening measurements

£190.19