IEC 62209-1:2016

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

06-07-2016

Superseded date

31-12-2021

£430.19
Excluding VAT
Summarise this standard

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Measurement system specifications
6 Protocol for SAR assessment
7 Uncertainty estimation
8 Measurement report
Annex A (normative) - Phantom specifications
Annex B (normative) - Calibration and characterization
        of dosimetric probes
Annex C (normative) - Post-processing techniques
Annex D (normative) - SAR measurement system verification
Annex E (normative) - Interlaboratory comparisons
Annex F (informative) - Definition of a phantom coordinate
        system and a device under test coordinate system
Annex G (informative) - SAR system validation sources
Annex H (informative) - Flat phantom
Annex I (informative) - Example recipes for phantom head
        tissue-equivalent liquids
Annex J (informative) - Measurement of the dielectric
        properties of liquids and uncertainty estimation
Annex K (informative) - Measurement uncertainty of specific
        fast SAR methods and fast SAR examples
Annex L (informative) - SAR test reduction supporting
        information
Annex M (informative) - Applying the head SAR test
        procedures
Annex N (informative) - Studies for potential hand effects on
        head SAR
Annex O (informative) - Quick start guide
Bibliography

IEC 62209-1:2016 specifies protocols and test procedures for measurement of the peak spatial-average SAR induced inside a simplified model of the head with defined reproducibility. It applies to certain electromagnetic field (EMF) transmitting devices that are positioned next to the ear, where the radiating structures of the device are in close proximity to the human head, such as mobile phones, cordless phones, certain headsets, etc. These protocols and test procedures provide a conservative estimate with limited uncertainty for the peak-spatial SAR that would occur in the head for a significant majority of people during normal use of these devices. The applicable frequency range is from 300 MHz to 6 GHz. This second edition cancels and replaces the first edition published in 2005. This edition constitutes a technical revision.

Committee
TC 106
DevelopmentNote
Stability Date: 2019. (07/2016)