IEC 62232:2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure
Hardcopy , PDF
English, French, English - French
23-08-2017
14-10-2022
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Quick start guide and how to use this document
6 Evaluation processes for product compliance, product
installation compliance and in-situ RF exposure assessments
7 Determining the evaluation method
8 Evaluation methods
9 Uncertainty
10 Reporting
Annex A (informative) - Source environment plane and
guidance on the evaluation method selection
Annex B (normative) - Evaluation methods
Annex C (informative) - Rationale supporting simplified
product installation criteria
Annex D (informative) - Guidance on comparing evaluated
parameters with a limit value
Annex E (informative) - Uncertainty
Annex F (informative) - Technology-specific guidance
Bibliography
IEC 62232:2017 provides methods for the determination of radio-frequency (RF) field strength and specific absorption rate (SAR) in the vicinity of radiocommunication base stations (RBS) for the purpose of evaluating human exposure. This document:
- considers intentionally radiating RBS which transmit on one or more antennas using one or more frequencies in the range 110 MHz to 100 GHz;
- considers the impact of ambient sources on RF exposure at least in the 100 kHz to 300 GHz frequency range;
- specifies the methods to be used for RF exposure evaluation for compliance assessment applications, namely:
- product compliance - determination of compliance boundary information for an RBS product before it is placed on the market;
- product installation compliance - determination of the total RF exposure levels in accessible areas from an RBS product and other relevant sources before the product is put into service;
- in-situ RF exposure assessment – measurement of in-situ RF exposure levels in the vicinity of an RBS installation after the product has been taken into operation;
- describes several RF field strength and SAR measurement and computation methodologies with guidance on their applicability to address both the in-situ evaluation of installed RBS and laboratory-based evaluations;
- describes how surveyors, with a sufficient level of expertise, establish their specific evaluation procedures appropriate for their evaluation purpose;
- provides guidance on how to report, interpret and compare results from different evaluation methodologies and, where the evaluation purpose requires it, determine a justified decision against a limit value and
- provides short descriptions of the informative example case studies given in the companion Technical Report IEC TR 62669]
This second edition cancels and replaces the first edition published in 2011 and constitutes a technical revision.
| Committee |
TC 106
|
| DevelopmentNote |
Stability Date: 2022. (08/2017)
|
| DocumentType |
Standard
|
| Pages |
240
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| AS IEC 62232:2018 | Identical |
| VDE 0848-232:2019-08 | Identical |
| NEN EN IEC 62232 : 2018 | Identical |
| CEI EN 62232 : 1ED 2018 | Identical |
| BS IEC 62232:2011 | Identical |
| I.S. EN 62232:2017 | Equivalent |
| ABNT NBR IEC 62232:2021 | Identical |
| EN 62232:2017 | Identical |
| NEN IEC 62232 : 2011 | Identical |
| UNE-EN 62232:2017 | Identical |
| PN EN 62232 : 2018 | Identical |
| BS EN 62232:2017 | Identical |
| DS EN 62232 : 2017 | Identical |