IEC 62471:2006
Current
The latest, up-to-date edition.
Photobiological safety of lamps and lamp systems
Hardcopy , PDF
English - French
26-07-2006
FOREWORD
INTRODUCTION
1. SCOPE
2. NORMATIVE REFERENCES
3. DEFINITIONS, SYMBOLS AND ABBREVIATIONS
4. EXPOSURE LIMITS (EL'S)
4.1 General
4.2 Specific factors involved in the determination
and application of retinal exposure limits
4.2.1 Pupil diameter
4.2.2 Angular subtense of source and measurement
field-of-view
4.3 Hazard exposure limits
4.3.1 Actinic UV hazard exposure limit for the skin
and eye
4.3.2 Near-UV hazard exposure limit for the eye
4.3.3 Retinal blue light hazard exposure limit
4.3.4 Retinal blue light hazard exposure limit - small
source
4.3.5 Retinal thermal hazard exposure limit
4.3.6 Retinal thermal hazard exposure limit - weak
visual stimulus
4.3.7 Infrared radiation hazard exposure limits for
the eye
4.3.8 Thermal hazard exposure limit for the skin
5. MEASUREMENT OF LAMPS AND LAMP SYSTEMS
5.1 Measurement conditions
5.1.1 Lamp ageing (seasoning)
5.1.2 Test environment
5.1.3 Extraneous radiation
5.1.4 Lamp operation
5.1.5 Lamp system operation
5.2 Measurement procedure
5.2.1 Irradiance measurements
5.2.2 Radiance measurements
5.2.3 Measurement of source size
5.2.4 Pulse width measurement for pulsed sources
5.3 Analysis methods
5.3.1 Weighting curve interpolations
5.3.2 Calculations
5.3.3 Measurement uncertainty
6. LAMP CLASSIFICATION
6.1 Continuous wave lamps
6.1.1 Exempt group
6.1.2 Risk Group 1 (Low-Risk)
6.1.3 Risk Group 2 (Moderate-Risk)
6.1.4 Risk Group 3 (High-Risk)
6.2 Pulsed lamps
ANNEX A (informative) SUMMARY OF BIOLOGICAL EFFECTS
Bioeffect datasheet #1: Infrared cataract
Bioeffect datasheet #2: Photokeratitis
Bioeffect datasheet #3: Photoretinitis
Bioeffect datasheet #4: Retinal thermal injury
Bioeffect datasheet #5: Ultraviolet cataract
Bioeffect datasheet #6: Ultraviolet erythema
ANNEX B (informative) MEASUREMENT METHOD
B.1 Instrumentation
B.1.1 Double monochromator: Recommended instrument
B.1.2 Broadband detectors
B.2 Instrument limitations
B.2.1 Noise equivalent irradiance
B.2.2 Instrument spectral response
B.2.3 Wavelength accuracy
B.2.4 Stray radiant power
B.2.5 Input optics for spectral irradiance
measurements: Recommendation
B.2.6 Linearity
B.3 Calibration sources
ANNEX C (informative) UNCERTAINTY ANALYSIS
ANNEX D (informative) GENERAL REFERENCES
Gives guidance for evaluating the photobiological safety of lamps and lamp systems including luminaires. Specifically it specifies the exposure limits, reference measurement technique and classification scheme for the evaluation and control of photobiological hazards from all electrically powered incoherent broadband sources of optical radiation, including LEDs but excluding lasers, in the wavelength range from 200 nm through 3000 nm. This standard was prepared as Standard CIE S 009:2002 by the International Commission on Illumination.
| Committee |
TC 76
|
| DevelopmentNote |
Also numbered as CIE S 009 (07/2006) Stability Date: 2017. (09/2017)
|
| DocumentType |
Standard
|
| Pages |
89
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Current
|
| Standards | Relationship |
| GOST R IEC 62471 : 2013 | Identical |
| DIN EN 62471:2009-03 | Identical |
| EN 62471:2008 | Identical |
| AS/NZS IEC 62471:2011 | Identical |
| VDE 0837-471:2009-03 | Identical |
| UNE-EN 62471:2009 | Identical |