• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 62505-1:2016

Current

Current

The latest, up-to-date edition.

Railway applications - Fixed installations - Particular requirements for AC switchgear - Part 1: Circuit-breakers with nominal voltage above 1 kV

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

03-02-2016

£190.19
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions [2]
5 Rating [4]
6 Design and construction [5]
7 Type tests [6]
8 Routine tests [7]
9 Guidance to the selection of circuit-breakers
   for service [8]
10 Information to be given with enquiries, tenders
   and orders [9]
11 Rules for transport, storage, installation, operation
   and maintenance [10]
12 Safety [11]
13 Influence of the product on the environment [12]
Bibliography

IEC 62505-1:2016 is applicable to single-pole and two-pole alternating current (AC) circuit-breakers which are designed for indoor or outdoor fixed installations in tractions systems, and operated with an AC line voltage and frequency as specified in IEC 60850:2014. The main changes with respect to the previous edition are as follows:
- reflect the latest versions of standards referenced and remove text already included in the IEC 62271 series;
- extend the scope to include single-pole and two-pole circuit-breakers;
- rework Table 1 according to the changes of IEC 62497-1:2010.

This publication is to be read in conjunction with IEC 62271-1:2007, and IEC 62271-100:2008.

Committee
TC 9
DevelopmentNote
To be used in conjunction with IEC 62271-1 and IEC 62271-100. Stability Date: 2018. (02/2016)
DocumentType
Standard
Pages
54
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

Standards Relationship
BS EN 61158-4-14:2008 Identical

IEC 62695:2014 Railway applications - Fixed installations - Traction transformers
IEC 62505-2:2016 Railway applications - Fixed installations - Particular requirements for AC switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV

IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 62128-1:2013 Railway applications - Fixed installations - Electrical safety, earthing and the return circuit - Part 1: Protective provisions against electric shock
IEC 60050-811:1991 International Electrotechnical Vocabulary (IEV) - Part 811: Electric traction
IEC 60050-605:1983 International Electrotechnical Vocabulary (IEV) - Part 605: Generation, transmission and distribution of electricity - Substations
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
IEC 62236-5:2008 Railway applications - Electromagnetic compatibility - Part 5: Emission and immunity of fixed power supply installations and apparatus
IEC 60376:2005 Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment
IEC 60850:2014 Railway applications - Supply voltages of traction systems
IEC 60913:2013 Railway applications - Fixed installations - Electric traction overhead contact lines
IEC 60050-447:2010 International Electrotechnical Vocabulary (IEV) - Part 447: Measuring relays
IEC 60296:2012 RLV Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
IEC 60137:2017 Insulated bushings for alternating voltages above 1000 V
IEC 62505-2:2016 Railway applications - Fixed installations - Particular requirements for AC switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV
IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 62497-1:2010+AMD1:2013 CSV Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electricaland electronic equipment
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 62498-2:2010 Railway applications - Environmental conditions for equipment - Part 2: Fixed electrical installations
IEC 62271-102:2001+AMD1:2011+AMD2:2013 CSV High-voltage switchgear and controlgear - Part 102: Alternatingcurrent disconnectors and earthing switches

£190.19
Excluding VAT