• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 62821-1:2015

Current

Current

The latest, up-to-date edition.

Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 1: General requirements

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

13-02-2015

£144.91
Excluding VAT

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Rated voltage
5 Marking
6 Core identification
7 General requirements for the construction of cables
8 Guide to use of the cables
Annex A (normative) - Code designation
Annex B (normative) - Assessment of halogens
Bibliography

IEC 62821-1:2015 applies to cables with insulation, and sheath if any, based on halogen-free, thermoplastic compound, and having low emission of smoke and corrosive gases when exposed to fire, of rated voltages up to and including 450/750 V used in power installations of nominal voltage not exceeding 450/750 V a.c.

Committee
TC 20
DevelopmentNote
Stability date: 2019. (02/2015)
DocumentType
Standard
Pages
47
PublisherName
International Electrotechnical Committee
Status
Current

14/30289997 DC : 0 BS EN 62893-1 - CHARGING CABLES FOR ELECTRIC VEHICLES - PART 1: GENERAL REQUIREMENTS
IEC 62893-3:2017 Charging cables for electric vehicles for rated voltages up to and including 0,6/1 kV - Part 3: Cables for AC charging according to modes 1, 2 and 3 of IEC 61851-1 of rated voltages up to and including 450/750 V
IEC 62930:2017 Electric cables for photovoltaic systems with a voltage rating of 1,5 kV DC
14/30313775 DC : 0 BS EN 62893-3 - CHARGING CABLES FOR ELECTRIC VEHICLES - PART 3: CABLES FOR AC CHARGING ACCORDING TO MODES 1, 2 AND 3 OF IEC 61851-1
IEC 62821-2:2015 Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 2: Test methods
IEC 62821-3:2015 Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 3: Flexible cables (cords)

IEC 60811-501:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
IEC 60228:2004 Conductors of insulated cables
IEC 60684-2:2011 Flexible insulating sleeving - Part 2: Methods of test
IEC 60811-505:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths
IEC 60811-504:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths
IEC 62821-3:2015 Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 3: Flexible cables (cords)
IEC 60227-2:1997+AMD1:2003 CSV Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 2: Test methods
IEC 60754-1:2011 Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content
IEC 60811-401:2012+AMD1:2017 CSV Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven
IEC 62821-2:2015 Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 2: Test methods
IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
IEC 60754-2:2011 Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity
IEC 60811-508:2012+AMD1:2017 CSV Electric and optical fibre cables - Test methods for non-metallic materials - Part 508: Mechanical tests - Pressure test at high temperature for insulation and sheaths
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
IEC 61034-2:2005+AMD1:2013 CSV Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements
IEC 62440:2008 Electric cables with a rated voltage not exceeding 450/750 V - Guide to use
IEC 60811-502:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 502: Mechanical tests - Shrinkage test for insulations

£144.91