IEEE C37.09-1999

Superseded

Superseded

View Superseded by

IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis

Available format(s)

PDF

Published date

28-03-2000

Superseded date

16-04-2019

Superseded by

IEEE C37.09-2018

£96.00
Excluding VAT
Summarise this standard

1. Scope
2. References
3. Definitions
4. Design tests
   4.1 Maximum voltage tests
   4.2 Power frequency tests
   4.3 Continuous current-carrying tests
   4.4 Dielectric withstand tests
   4.5 Standard operating duty (standard duty cycle) tests
   4.6 Interrupting time tests
   4.7 TRV tests
   4.8 Short-circuit current interrupting tests
   4.9 Load current
   4.10 Capacitor switching current tests
   4.11 Line closing switching surge factor
   4.12 Out-of-phase switching current tests
   4.13 Mechanical endurance tests
   4.14 Control voltage
   4.15 Fluid operating pressure
   4.16 Design tests on pressurized components
   4.17 Sealed pressure systems leakage tests
5. Production tests
   5.1 Types of tests
   5.2 Current and linear coupler transformer tests
   5.3 High-voltage circuit breaker bushings tests
   5.4 Gas receiver tests
   5.5 Pressure tests
   5.6 Nameplate check
   5.7 Leakage tests
   5.8 Vacuum integrity tests
   5.9 Resistors, heaters, and coils check tests
   5.10 Control and secondary wiring check tests
   5.11 Clearance and mechanical adjustment check tests
   5.12 Mechanical operation tests
   5.13 Timing tests
   5.14 Stored energy system tests
   5.15 Electrical resistance of current path test
   5.16 Power-frequency withstand voltage tests on major
        insulation components
   5.17 Power-frequency withstand voltage tests on control
        and secondary wiring
6. Conformance test
   6.1 Outdoor circuit breakers
   6.2 Indoor circuit breakers
7. Standard methods for determining the values of a sinusoidal
   current wave and a power-frequency recovery voltage
   7.1 Currents
   7.2 Power-frequency recovery voltage
Annex A (informative) - Records and reports of type tests for
                        making, breaking and short-time current
                        performance
Annex B (informative) - Test tables from C37.09-1979

Summarizes the various tests that are made on ac high voltage indoor and outdoor circuit breakers, except for generator circuit breakers, which are covered in IEEE Std C37.013-1997. Also describes accepted methods used in making the tests and specifies the tests that will verify assigned ratings under ANSI/IEEE standards.

Committee
Switchgear
DevelopmentNote
Supersedes IEEE DRAFT C37.09. (06/2000) Amendment 1 to IEEE C37.09 is available separately, see IEEE C37.09A. (09/2005) Amendment 2 to IEEE C37.09 is available separately, see IEEE C37.09B. (06/2011) NEW CHILD ERR 1 IS NOW ADDED
DocumentType
Standard
Pages
69
ProductNote
NEW CHILD COR 1 IS NOW ADDED NEW CHILD ERR 1 IS NOW ADDED New child AMD 2 2010 is now added New child AMD 1 2005 is now added.
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded
SupersededBy
Supersedes

⚠

A newer version of this standard is available.

View Current Edition
£96.00
Excluding VAT