• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

NBN EN 61098 : 2007

Current

Current

The latest, up-to-date edition.

RADIATION PROTECTION INSTRUMENTATION - INSTALLED PERSONNEL SURFACE CONTAMINATION MONITORING ASSEMBLIES

Published date

12-01-2013

1 Scope and object
2 Normative references
3 Terms and definitions
4 Classification of assemblies
   4.1 According to type of radiation to be measured
   4.2 According to type of surface
   4.3 According to type
5 Design characteristics
   5.1 Positioning of user
   5.2 Size of user
   5.3 Hand monitoring facilities
   5.4 Foot monitoring facilities
   5.5 Body monitoring facilities
   5.6 Visual display
   5.7 Audible indicators
   5.8 Monitoring period
   5.9 Ease of decontamination
   5.10 Detectors used
6 Performance requirements and test procedures
   6.1 General test procedure
   6.2 Statistical fluctuations
   6.3 Reference sources
   6.4 Nature of tests
   6.5 Use of gas flow detectors
7 Radiation characteristics
   7.1 Variation of response with source position
   7.2 Background
   7.3 Decision threshold (minimum detectable surface
        emission rate)
   7.4 Variation of response with energy
   7.5 Response to other ionising radiations
   7.6 Type and routine tests of performance
   7.7 Linearity of indication
8 Overload protection
   8.1 Requirements
   8.2 Method of test
9 Availability
   9.1 Warm-up time
   9.2 Power failure
10 Environmental conditions
   10.1 Temperature
   10.2 Relative humidity
   10.3 Atmospheric pressure
11 Power supply
   11.1 Voltage and frequency
   11.2 Electromagnetic compatibility
12 Storage
13 Documentation
   13.1 Certificate
   13.2 Operation and maintenance manual
   13.3 Operational instructions
   13.4 Type test report
Annex A (informative) Explanation of the derivation of
        minimum detectable surface emission rate formula
Annex ZA (informative) Examples of possible additional
         tests for further characterization of the sensitive
         volume
Annex ZB (informative) Summation of information from adjacent
         detectors
Annex ZC (normative) Normative references to international
         publications with their corresponding European
         publications

Applies to contamination warning assemblies and monitors used for the monitoring of radioactive contamination on the surface of personnel whether they be clothed or not.

DocumentType
Standard
PublisherName
Belgian Standards
Status
Current

Standards Relationship
DIN EN 61098 : 2008 Identical
EN 61098:2007 Identical
BS EN 61098:2007 Identical
I.S. EN 61098:2007 Identical
NF EN 61098 : 2008 Identical

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.