1 Domaine d'application
2 Références normatives
3 Définitions
4 Exigences générales
5 Généralités sur les essais
6 Caractéristiques assignées
7 Classification
8 Marquage
9 Vérification des dimensions
10 Protection contre les chocs électriques
11 Dispositions pour la mise à la terre
12 Bornes
13 Prescriptions de construction
14 Mécanisme
15 Résistance au vieillissement, protection procurée
    par les enveloppes des interrupteurs et résistance
    à l'humidité
16 Résistance d'isolement et rigidité diélectrique
17 Echauffement
18 Pouvoir de fermeture et de coupure
19 Fonctionnement normal
20 Résistance mécanique
21 Résistance à la chaleur
22 Vis, pièces transportant le courant et connexions
23 Lignes de fuite, distances dans l'air et distances à
    travers la matière de remplissage
24 Résistance de la matière isolante à la chaleur anormale,
    au feu et aux courants de cheminement
25 Protection contre la rouille
26 Exigences de compatibilité électromagnétique
101 Fonctionnement anormal
102 Eléments constituants
Annexe A (normative) Nombre d'échantillons nécessaires
         pour les essais
Annexe B (normative) Exigences supplémentaires pour les
         interrupteurs ayant des dispositifs de sortie
         et de retenue pour câbles souples
Annexe AA (normative) Exemples de types d'interrupteurs
          électroniques avec leurs fonctions
Annexe BB (normative) Mesure des distances d'isolement et
          des lignes de fuite
Annexe CC (normative) Réglages d'essai
Annexe ZA (informative) Divergences A
Annexe ZZ (informative) Couverture des Exigences Essentielles
          des Directives CE

Describes HBES switches with a working voltage not exceeding 250 V a.c. and a rated current up to and including 16 A. for household and similar fixed electrical installations either indoors or outdoors and to associated electronic extension units.

DevelopmentNote
Indice de classement: C61-105. PR NF EN 50428 August 2004. (08/2004)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Current

NF EN 61558-2-6 : 2009 SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND SIMILAR PRODUCTS FOR VOLTAGES UP TO 1100 V - PART 2-6: PARTICULAR REQUIREMENTS AND TESTS FOR SAFETY ISOLATING TRANSFORMERS AND POWER SUPPLY UNITS INCORPORATING SAFETY ISOLATING TRANSFORMERS
NF EN 55022 : 2012 INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT
HD 384.4.41 S2:1996/A1:2002 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 41: PROTECTION AGAINST ELECTRIC SHOCK
IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
NF EN 60664-1 : 2007 INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS
NF EN 61140 : 2016 PROTECTION AGAINST ELECTRIC SHOCK - COMMON ASPECTS FOR INSTALLATION AND EQUIPMENT
IEC 60669-2-1:2002+AMD1:2008+AMD2:2015 CSV Switches for household and similar fixed electrical installations -Part 2-1: Particular requirements - Electronic switches
ETSI EN 300 220-3 V1.1.1 (2000-09) ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SHORT RANGE DEVICES (SRD); RADIO EQUIPMENT TO BE USED IN THE 25 MHZ TO 1 000 MHZ FREQUENCY RANGE WITH POWER LEVELS RANGING UP TO 500 MW; PART 3: HARMONIZED EN COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE
IEC 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
NF EN 50090-2-2 : 97 AMD 2 2009 HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 2-2: SYSTEM OVERVIEW - GENERAL TECHNICAL REQUIREMENTS
ETSI EN 301 489-3 V1.6.1 (2013-08) Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
NF EN 60669 2-1 : 2004 AMD 12 2011 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATION - PART 2-1: PARTICULAR REQUIREMENTS - ELECTRONIC SWITCHES
IEC 60669-1:2017 Switches for household and similar fixed-electrical installations - Part 1: General requirements
NF EN 50065-1 : 2012 SIGNALING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 1: GENERAL REQUIREMENTS, FREQUENCY BANDS AND ELECTROMAGNETIC DISTURBANCES
NF EN 50065-2-1 : 2003 AMD 1 2006 SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 2-1: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 95 KHZ TO 148,5 KHZ AND INTENDED FOR USE IN RESIDENTIAL, COMMERCIAL AND LIGHT INDUSTRIAL ENVIRONMENTS
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
ETSI EN 300 220-1 V2.4.1 (2012-05) Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with power levels ranging up to 500 mW; Part 1: Technical characteristics and test methods
NF EN 50065-2-3 : 2003 AMD 1 2006 SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 2-3: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 3 KHZ TO 95 KHZ AND INTENDED FOR USE BY ELECTRICITY SUPPLIERS AND DISTRIBUTORS
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
NF EN 60669-1 : 2000 AMD 2 2009 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED-ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS
NF C15-100:2002/A5 LOW-VOLTAGE ELECTRICAL INSTALLATIONS

Sorry this product is not available in your region.