• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

NFC 33 253 : 2006

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

INSULATED CABLES FOR POWER SYSTEMS - SINGLE-CORE CABLES WITH POLYMERIC INSULATION FOR RATED VOLTAGES ABOVE 150 KV (UM = 170 KV) UP TO 500 KV (UM = 525 KV)

Published date

12-01-2013

Superseded date

01-08-2008

Superseded by

NFC 33 254 : 2016

Sorry this product is not available in your region.

AVANT-PROPOS
1 Généralités
  1.1 Domaine d'application
  1.2 Références normatives
  1.3 Définitions
  1.4 Tension assignée
  1.5 Renseignements à fournir lors d'une commande
  1.6 Marques et indications
  1.7 Essais des accessoires
  1.8 Absence de gaz dans les câbles isolés au polyéthylène
      réticulé
  1.9 Protection pour la livraison
2 Capacité de transport
3 Constitution (à titre indicatif)
4 Caractéristiques des constituants
  4.1 Ame
  4.2 Enveloppe isolante
  4.3 Écrans sur âme et sur enveloppe isolante
  4.4 Ensemble écran-gaine
  4.5 Dispositif destiné à l'étanchéité longitudinale
  4.6 Diamètre extérieur du câble
5 Propriétés du câble terminé
  5.1 Généralités
  5.2 Essais non électriques sur câble complet
  5.3 Essais électriques sur câble complet et accessoires
  5.4 Essais de tenue diélectrique sur longueurs de livraison
6 Procédures d'acceptation de type et de réception
  6.1 Classification des essais
  6.2 Acceptation de type
  6.3 Réception
  6.4 Controles en cours de fabrication
7 Essais après pose
  7.1 Essai diélectrique de l'enveloppe isolante
  7.2 Essais diélectriques de la gaine extérieure
8 Extension de l'acceptation de type en fonction de la
  section de l'âme
9 Extension de l'acceptation de type en fonction de la
  tension
ANNEXE A (normative) - Essais sur l'ensemble écran gaine
ANNEXE B (normative) - Méthodes de mesure des rétractions
                       de l'enveloppe isolante et de la
                       gaine extérieure
ANNEXE C (normative) - Essai de court-circuit
ANNEXE D (normative) - Intensités admissibles
ANNEXE E (informative) - Calcul du courant de court-circuit
                         en tenant compte des effets de
                         l'asymétrie supposée maximale
ANNEXE F (normative) - Préparation des éprouvettes dans le
                       cas de vieillissement thermique sur
                       tronçons

DevelopmentNote
Indice de classement: C33-253. XP NFC 33 253 March 1995. (10/2004) PR NFC 33 253 July 2005 (07/2005)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy

NFC 33 062 : 1999 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - SF6 INSULATED METAL ENCLOSED TERMINATIONS FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 500 KV (UM EQUAL TO 525 KV)
NFC 33 065 : 2001 XP INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - SELF SUPPORTING OUTDOOR POLYMERIC TERMINATIONS OF TERMINATIONS WITH A COMPOSITE HOUSING, WITHOUT PORCELAIN INSULATOR, FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 150 KV (UM = 170 KV) UP TO 500 KV (UM = 550 KV)
NFC 33 061 : 1999 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - JOINTS FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 500 KV (UM EQUAL TO 525 KV)

NF EN 60811-4-1 : 2004 INSULATING AND SHEATHING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 4-1: METHODS SPECIFIC TO POLYETHYLENE AND POLYPROPYLENE COMPOUNDS - RESISTANCE TO ENVIRONMENTAL STRESS CRACKING - MEASUREMENT OF THE MELT FLOW INDEX - CARBON BLACK AND/OR MINERAL FILLER CONTENT MEASUREMENT IN POLYETHYLENE BY DIRECT COMBUSTION - MEASUREMENT OF CARBON BLACK CONTENT
NF EN 60811 3-2 : 1996 AMD 2 2004 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 3: METHODS SPECIFIC TO PVC COMPOUNDS - SECTION 2: LOSS OF MASS TEST - THERMAL STABILITY TEST
NF EN 60230 : 2003 IMPULSE TESTS ON CABLES AND THEIR ACCESSORIES
NF EN 60071-1 : 2006 AMD 1 2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
NFC 33 220 : 88 AMD 1 88 INSULATED OR PROTECTED CABLES FOR POWER SYSTEMS - EXTRUDED SOLID DIELECTRIC INSULATED CABLES FOR RATED VOLTAGES FROM 1.8/3(3.6) KV UP TO 18/30(36) KV
NFC 41 101 : 1995 HIGH VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS
IEC 60949:1988 Calculation of thermally permissible short-circuit currents, taking into account non-adiabatic heating effects
NFC 01 461 : 2008 INTERNATIONAL ELECTROTECHNICAL VOCABULARY - PART 461: ELECTRIC CABLES
NFC 32 013 : 1981 INSULATED CABLES AND FLEXIBLE CORDS - CONDUCTORS OF INSULATED CABLES
NFC 32 070 : 2001 AMD 1 2005 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CLASSIFICATION TESTS ON CABLES AND CORDS WITH RESPECT TO THEIR BEHAVIOUR TO FIRE
IEC 60067:1966 Dimensions of electronic tubes and valves
NF EN 60811 1-1 : 96 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 1: MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING THE MECHANICAL PROPERTIES
NF EN 60811 3-1 : 96 AMD 2 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 3: METHODS SPECIFIC TO PVC COMPOUNDS - SECTION 1: PRESSURE TEST AT HIGH TEMPERATURE - TESTS FOR RESISTANCE TO CRACKING
NFT 51 223 : 1985 PLASTICS - SEMI-CRYSTALLINE MATERIALS - DETERMINATION OF THE CONVENTIONAL MELTING TEMPERATURE BY THERMAL ANALYSE
NF EN 60811 1-2 : 96 AMD 2 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 2: THERMAL AGEING METHODS
NF EN 60811-2-1 : 99 AMD 1 2002 INSULATING AND SHEETING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 2-1: METHODS SPECIFIC TO ELASTOMERIC COMPOUNDS - OZONE RESISTANCE, HOT SET AND MINERAL OIL IMMERSION TESTS
NF EN 60811 1-4 : 96 AMD 2 2002 INSULATING AND SHEETING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 4: TEST AT LOW TEMPERATURE

Sorry this product is not available in your region.