NFPA 17:2024
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard for Dry Chemical Extinguishing Systems
13-05-2023
23-05-2026
Chapter 1 Administration 1.1 Scope. 1.2 Purpose. 1.3 Retroactivity. 4.11 Indicators. 4.12 Assembly. 1.6 Qualifications. Chapter 2 Referenced Publications 2.1 General. 2.2 NFPA Publications. 2.3 Other Publications. 2.4 References for Extracts in Mandatory Sections. Chapter 3 Definitions 3.1 General. 3.2 NFPA Official Definitions. 3.3 General Definitions. 3.4 Systems Definitions. Chapter 4 Components 4.1 General. 4.2 Detectors. 4.3 Hose Line. 4.4 Nozzles. 4.5 Operating Devices. 4.6 Pipe and Fittings. 4.7 Dry Chemical. 4.8 Expellant Gas. 4.9 Electrical Wiring and Equipment. 4.10 Storage Containers. 4.11 Indicators. 4.12 Assembly. Chapter 5 System Requirements 5.1 Use and Limitations. 5.2 Multiple Systems Protecting a Common Hazard. 9.6 System Supervision. 9.7 Review and Certification. 5.5 Special Considerations. 5.6 Personnel Safety. 5.7 Operation and Control of Systems. 5.8 Dry Chemical and Expellant Gas Supply. 5.9 Piping. Chapter 6 Total Flooding Systems 6.1 General. 6.2 Hazard Specifications. Chapter 7 Local Application Systems 7.1 Uses. 7.2 Hazard Specifications. Chapter 8 Hand Hose Line Systems 8.1 Separate Supplies. 8.2 Location, Spacing, and Actuation. 8.3 Dry Chemical Requirements. 8.4 Training. Chapter 9 Pre-Engineered Systems 9.1 Uses. 9.2 Types of Systems. 9.3 Commercial Kitchen Hood, Duct, and Cooking Appliance Systems. 9.4 Manual Actuation Requirements. 9.5 System Annunciation Requirements. 9.6 System Supervision.9.7 Review and Certification. 9.8 Vehicle Fueling Service Station Systems. 9.9 Systems for the Protection of Mobile Equipment. 9.10 Hand Hose Line Systems. 10.2 Plans. 10.3 Approval of Plans. 10.4 Approval of Installations. 10.5 Manual. Chapter 11 Inspection, Maintenance, and Recharging 11.1 General Requirements. 11.2 Owner’s Inspection. 11.3 Maintenance. 11.4 Recharging. 11.5 Hydrostatic Testing. Annex A Explanatory Material Annex B Common Deficiencies and Impairments Annex C Informational References
This standard includes minimum requirements for dry chemical fire-extinguishing systems that discharge dry chemical from fixed nozzles or hand hose lines by means of expellant gas.
| DocumentType |
Standard
|
| PublisherName |
National Fire Protection Association
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |