AS/NZS 4509.1:2009

Current

Current

Stand-alone power systems Safety and installation

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

21-12-2009

£67.62
Excluding VAT
Summarise this standard

This Standard sets out safety and installation requirements for stand-alone power systems used for the supply of extra-low (ELV) and/or low voltage (LV) electric power to a single load, or an electrical installation in a single residence or building, or a group of residences or buildings and associated items with switchboards to AS/NZS 3000 requirements.

Committee
EL-042
DocumentType
Standard
ISBN
0 7337 9343 6
Pages
36
ProductNote
Reconfirmed 20/01/2017.This standard has been reconfirmed in Australia in 2017 and remains current in New Zealand. Reconfirmation Notice 20/01/2017
PublisherName
Standards Australia
Status
Current
SupersededBy
Supersedes

This Standard sets out safety and installation requirements for stand-alone power systems used for the supply of extra-low (ELV) and/or low voltage (LV) electric power to a single load, or an electrical installation in a single residence or building, or a group of residences or buildings and associated items with switchboards to AS/NZS 3000 requirements.This Standard covers - (a) equipment up to, and including, the output of the stand-alone power system (i.e. the point of supply-see the definition in Clause 1.4.12); and(b) direct connection of a stand-alone power system to - (i) a single load (e.g. a water pump);(ii) a single electrical installation (e.g. a residence); or(iii) a group of independent electrical installations (e.g. a number of separate residences and/or buildings).This Standard includes minimum rating and over-current protection requirements for the consumers mains and earthing arrangements.NOTE: The connection from the output of the stand-alone power system to the electrical installation is regarded as the consumers mains (see AS/NZS 3000).This Standard, with additional safety requirements, shall be applied to systems with energy storage at LVSystem design considerations are detailed in AS 4509.2.NOTE: System maintenance matters are considered in Appendix A.

Originated in Australia as AS 4509.1-1999 and AS 4509.3-1990.
Jointly revised, amalgamated and designated as AS/NZS 4509.1:2009.

Frequently Asked Questions

AS/NZS 4509.1 provides requirements and guidance for designing and installing stand-alone power systems using renewable and conventional sources. It is a joint Australian and New Zealand standard published by Standards Australia and Standards New Zealand.

AS/NZS 4509.1 applies to off-grid electrical supply systems for homes, remote facilities and similar applications. It is a joint Australian and New Zealand standard published by Standards Australia and Standards New Zealand.

AS/NZS 4509.1 provides requirements and guidance for designing and installing stand-alone power systems using renewable and conventional sources. It applies to off-grid electrical supply systems for homes, remote facilities and similar applications.

Yes — AS/NZS 4509.1 is a joint Australian and New Zealand standard published by Standards Australia and Standards New Zealand, and applies in both countries.

AS/NZS 4509.1 is published by Standards Australia and Standards New Zealand. It is a joint Australian and New Zealand standard.