UNE-EN ISO 4589-3:2017

Current

Current

The latest, up-to-date edition.

Plastics - Determination of burning behaviour by oxygen index - Part 3: Elevated-temperature test (ISO 4589-3:2017)

Available format(s)

Hardcopy , PDF

Language(s)

Spanish, Castilian, English

Published date

04-10-2017

£67.82
Excluding VAT

This part of ISO 4589 specifies methods for determining the minimum volume fraction of oxygen, in a mixture

with nitrogen, that will support combustion of small vertical test specimens under specified test conditions over

a range of temperatures between 25 °C and 150 °C. The range of temperatures is typically between 40 °C

and 150 °C. The results are defined as temperature index values at the test temperature, which is typical of

the practical temperature that a plastic material may experience in an overheated service situation.



Methods are provided for testing materials that are self-supporting at the test temperature in the form of

vertical bars or sheet up to 10,5 mm thick. However, they are not applicable to form V which requires

supporting frame as defined in Table 2 of Part 2. These methods are suitable for solid, laminated or cellular

materials characterized by an apparent density 100 kg/m3 or greater. The methods may also be applicable to

some cellular materials having an apparent density of less than 100 kg/m3. A method is provided for testing

flexible sheet or film materials while supported vertically.



This part of ISO 4589 also includes a method (see Annex A) for determining the temperature at which the

oxygen index of small vertical test specimens in air is 20,9 % under specified test conditions. The temperature

at which this occurs is defined as the flammability temperature (FT) and the method is limited to the

determination of temperatures less than 400 °C. The method is not applicable to materials having an oxygen

index of < 20,9 %.



Results obtained in accordance with this part of ISO 4589 is not applicable to describe or appraise the fire

hazard presented by a particular material or shape under actual fire conditions, unless used as one element of

a fire risk assessment which takes into account all of the factors which are pertinent to the assessment of the

fire hazard of a particular application for the material.



NOTE 1 It may not be possible to apply these methods satisfactorily to materials that exhibit high levels of shrinkage

when heated, e.g. highly oriented thin film.



NOTE 2 For assessing the flame propagation properties of cellular materials of density < 100 kg/m3, attention is drawn

to the method of ISO 3582:2000, Flexible cellular polymeric materials çø Laboratory assessment of horizontal burning

characteristics of small specimens subjected to a small flame.

Committee
CTN 53/SC 6
DocumentType
Standard
Pages
29
PublisherName
Asociación Española de Normalización
Status
Current

ISO 3582:2000 Flexible cellular polymeric materials — Laboratory assessment of horizontal burning characteristics of small specimens subjected to a small flame
ISO 13943:2017 Fire safety — Vocabulary
ISO 4589-2:2017 Plastics — Determination of burning behaviour by oxygen index — Part 2: Ambient-temperature test
ISO 4589-1:2017 Plastics — Determination of burning behaviour by oxygen index — Part 1: General requirements

£67.82
Excluding VAT