CSA C22.2 No. 5 : 2013
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
MOLDED-CASE CIRCUIT BREAKERS, MOLDED-CASE SWITCHES AND CIRCUIT-BREAKER ENCLOSURES
Hardcopy , PDF
08-18-2021
English
01-01-2013
PREFACE
INTRODUCTION
1 Scope
2 Definitions
3 Components
4 Units of Measurement
5 Reference Publications
MOLDED CASE CIRCUIT BREAKERS
6 Construction
7 Tests
8 Ratings
9 Markings
MOLDED CASE SWITCHES
10 Construction
11 Performance
12 Ratings
13 Markings
ACCESSORIES
14 Construction
15 Performance
16 Ratings
17 Markings
ENCLOSURES
18 Construction
19 Performance (Short-Circuit Current Ratings)
20 Ratings
21 Markings
Annex A (Informative) - Standards for Components
Annex B (Normative) - Referenced Standards
Annex C (Normative) - Circuit Calibration and Instrumentation
Test Circuits
Annex D (Informative) - French and Spanish Translations and
Markings
Annex E (For Canada Only - Informative) - Guidelines for
Ground Fault Protection Equipment
Annex F (Informative) - Recommended Symbols and
Abbreviations for the Marking of All Products
SUPPLEMENT SA - MOLDED-CASE CIRCUIT BREAKERS, MOLDED-CASE
SWITCHES, AND CIRCUIT-BREAKER ENCLOSURES (MARINE
USE) FOR USE UNDER USCG ELECTRICAL SYSTEMS
REGULATIONS SUBCHAPTER S (33 CFR, PART 183) AND
USCG ELECTRICAL ENGINEERING REGULATIONS
SUBCHAPTER J (46 CFR, PARTS 110 - 113)
INTRODUCTION
CONSTRUCTION
PERFORMANCE
MARKINGS
SUPPLEMENT SB - MOLDED-CASE CIRCUIT BREAKERS, MOLDED-CASE
SWITCHES, AND CIRCUIT-BREAKER ENCLOSURES (NAVAL
USE)
INTRODUCTION
PERFORMANCE
MARKINGS
SUPPLEMENT SC - MOLDED-CASE CIRCUIT BREAKERS AND MOLDED-CASE
SWITCHES FOR USE WITH BATTERY POWER SUPPLIES
INTRODUCTION
CONSTRUCTION
PERFORMANCE
RATINGS
MARKINGS
SUPPLEMENT SD - CLASSIFIED CIRCUIT BREAKERS FOR USE WITH
SPECIFIED PANELBOARDS AS AN ALTERNATE FOR
SPECIFIED CIRCUIT BREAKERS
INTRODUCTION
CONSTRUCTION
PERFORMANCE
MARKINGS
SUPPLEMENT SE - MOLDED-CASE CIRCUIT BREAKERS AND MOLDED-CASE
SWITCHES WITH SOFTWARE IN PROGRAMMABLE
COMPONENTS
SUPPLEMENT SF - ADDITIONAL TESTS FOR CIRCUIT BREAKERS WITH
ELECTRONIC OVERCURRENT PROTECTION
SUPPLEMENT SG - ELECTROMAGNETIC COMPATIBILITY (EMC) -
REQUIREMENTS AND TEST METHODS FOR CIRCUIT
BREAKERS
SUPPLEMENT SH - MOLDED-CASE CIRCUIT BREAKERS WITH ADDITIONAL
MOTOR OVERLOAD PROTECTION
INTRODUCTION
CONSTRUCTION
PERFORMANCE
Contains molded-case circuit breakers, circuit breaker and ground-fault circuit-interrupters, fused circuit breakers, high-fault protectors, and high-fault modules.
DevelopmentNote |
Also numbered as UL 489 & NMX-J-266-ANCE. (04/2004) Supersedes CSA C22.2.5 PT1 and CSA C22.2.5 PT2. (06/2006)
|
DocumentType |
Standard
|
Pages |
384
|
PublisherName |
Canadian Standards Association
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
CSA C22.2 No. 42 : 2010 : INC : UPD 2 : 2016 : R201500 | GENERAL USE RECEPTACLES, ATTACHMENT PLUGS, AND SIMILAR WIRING DEVICES |
C22.2 NO. 31-18 | Switchgear assemblies |
C22.2 NO. 269.3-17 | Surge protective devices - Type 3 - Cord connected, direct plug-in and receptacle type |
CSA C22.2 No. 27 : 2009 : INC : UPD 1 : 2011 | BUSWAYS |
CSA C22.2 No. 1 : 2004 | AUDIO, VIDEO AND SIMILAR ELECTRONIC EQUIPMENT |
CSA C22.2 No. 107.3 : 2014 | UNINTERRUPTIBLE POWER SYSTEMS |
CSA Z463 : 2013 | GUIDELINE ON MAINTENANCE OF ELECTRICAL SYSTEMS |
CSA C22.2 No. 218.2 : 2015 | HYDROMASSAGE BATHTUB APPLIANCES |
CSA C22.2 No. 270 : 2016 | ARC FAULT PROTECTIVE DEVICES |
C22.2 NO. 269.4-17 | Surge protective devices - Type 4 - Component assemblies |
SAE J2698_201411 | Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design—Truck and Bus |
C22.2 NO. 229-17 | Switching and metering centres |
C22.2 NO. 280-16 | Electric vehicle supply equipment (Tri-national standard, with UL 2594 and NMX-J-677-ANCE-2016) |
CSA C22.2 No. 29 : 2015 | PANELBOARDS AND ENCLOSED PANELBOARDS |
C22.1-15 PACKAGE | Consists of C22.1-15, Canadian electrical code, part I (23rd edition), safety standard for electrical installations; C22.1HB-15, Canadian electrical code handbook - an explanation of rules of the Canadian electrical code, part I and the 2015 Electrical quick reference |
C22.2 NO. 269.1-17 | Surge protective devices - Type 1 - Permanently connected |
CSA C22.2 No. 39 : 2013 | FUSEHOLDER ASSEMBLIES |
CSA C22.2 No. 5 PT2 : 1990 | MOULDED CASE SWITCHES |
C22.1HB-18 | Canadian Electrical Code Handbook - An Explanation of the Rules of the Canadian Electrical Code, Part I |
NEMA ICS 6-1993 (R2006) | Industrial Control and Systems: Enclosures |
ANSI/NEMA AB 3:2013 | Molded-Case Circuit Breakers and Their Application |
CSA C22.2 No. 42 : 2010 : INC : UPD 1 : 2013 | GENERAL USE RECEPTACLES, ATTACHMENT PLUGS, AND SIMILAR WIRING DEVICES |
CSA C22.2 No. 274 : 2017 | ADJUSTABLE SPEED DRIVES |
CSA C22.2 No. 88 : 1958 : R2008 | CONSTRUCTION AND TEST OF INDUSTRIAL HEATING EQUIPMENT |
CSA C22.2 No. 273 : 2014(R2019) | CABLEBUS |
CSA C22.2 No. 244 : 2005 : R2010 | SWITCHBOARDS |
CSA C22.2 No. 88 : 1958 : R2013 | CONSTRUCTION AND TEST OF INDUSTRIAL HEATING EQUIPMENT |
CSA C22.2 No. 88 : 1958 : R2017 | CONSTRUCTION AND TEST OF INDUSTRIAL HEATING EQUIPMENT |
IEEE 1458-2005 | IEEE Recommended Practice for the Selection, Field Testing, and Life Expectancy of Molded Case Circuit Breakers for Industrial Applications |
CSA C22.2 No. 144.1 : 2016 | GROUND-FAULT CIRCUIT-INTERRUPTERS |
UL 1682:5ED 2017-02-15 | Plugs, Receptacles, and Cable Connectors of the Pin and Sleeve Type |
CSA C22.2 No. 60335-1:2011 | SAFETY OF HOUSEHOLD AND SIMILAR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 272 : 2014 | WIND TURBINE ELECTRICAL SYSTEMS |
UL 943:5ED 2016-05-17 | Ground-Fault Circuit-Interrupters |
UL 1778:5ED 2014-06-13 | Uninterruptible Power Systems |
CSA C22.2 No. 263 : 2015 | FIRE PUMP CONTROLLERS |
CSA C22.2 No. 305 : 2016 | MOLDED-CASE CIRCUIT BREAKERS, MOLDED-CASE SWITCHES, AND CIRCUIT-BREAKER ENCLOSURES FOR USE WITH PHOTOVOLTAIC (PV) SYSTEMS |
CAN/CSA-C22.2 NO. 60335-1:11 (R2016) | Safety of household and similar appliances - Part 1: General requirements (Tri-national standard, with NMX-J-521/1-ANCE and UL 60335-1) |
UL 60335-1:6ED 2016-10-31 | Standard for Safety of Household and Similar Appliances, Part 1: General Requirements |
C22.2 NO. 292-18 | Dc arc fault protection for photovoltaic applications |
CSA C22.2 No. 269 PACKAGE : 2017 | CONSISTS OF C22.2 NO. 269.1-17 - SURGE PROTECTIVE DEVICES - TYPE 1 - PERMANENTLY CONNECTED; C22.2 NO. 269.2-17 - SURGE PROTECTIVE DEVICES - TYPE 2 - PERMANENTLY CONNECTED; C22.2 NO. 269.3-17 - SURGE PROTECTIVE DEVICES - TYPE 3 - CORD CONNECTED, DIRECT PLUG-IN AND RECEPTACLE TYPE; C22.2 NO. 269.4-17 - SURGE PROTECTIVE DEVICES - TYPE 4 - COMPONENT ASSEMBLIES AND C22.2 NO. 269.5-17 - SURGE |
C22.2 NO. 14-18 | Industrial control equipment |
CSA C22.2 No. 254 : 2005(R2015) | MOTOR CONTROL CENTRES |
CSA C22.2 NO. 60947-4-1:14 (R2019) | Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters ( Bi-national standard, with UL 60947-4-1) |
CSA C22.2 No. 27 : 2009 : R2013 | BUSWAYS |
CSA C22.2 No. 244 : 2005 : INC : UPD 1 : 2012 : R201000 | SWITCHBOARDS |
CSA B44.1 : 2014 | ELEVATOR AND ESCALATOR ELECTRICAL EQUIPMENT |
C22.2 NO. 330-17 | Photovoltaic rapid shutdown systems |
C22.2 NO. 182.1-17 | Plugs, receptacles, and cable connectors of the pin and sleeve type (Trinational standard with NMX-J-719-ANCE and UL 1682) |
CSA C22.2 No. 178.1 : 2014 | TRANSFER SWITCH EQUIPMENT |
C22.2 NO. 269.5-17 | Surge protective devices - Type 5 - Components |
CSA C22.2 No. 0.19 : 2010 : R2015 | REQUIREMENTS FOR SERVICE ENTRANCE EQUIPMENT |
CSA C22.2 No. 255 : 2004 : R2014 | NEON TRANSFORMERS AND POWER SUPPLIES |
UL 1008A:2ED 2017-09-05 | Transfer Switch Equipment, Over 1000 Volts |
CSA C22.2 NO. 178.3:17 | Transfer switch equipment, over 1000 volts (Binational standard with UL 1008A) |
CSA C22.2 No. 42 : 2010 | GENERAL USE RECEPTACLES, ATTACHMENT PLUGS, AND SIMILAR WIRING DEVICES |
CSA C22.2 No. 107.1 : 2016 | POWER CONVERSION EQUIPMENT |
CSA C22.2 No. 42 : 2010 : R2015 | GENERAL USE RECEPTACLES, ATTACHMENT PLUGS, AND SIMILAR WIRING DEVICES |
C22.2 NO. 300-18 | Portable power equipment |
CSA C22.2 No. 42 : 2010 : INC : UPD 3 : 2017 : R201500 | GENERAL USE RECEPTACLES, ATTACHMENT PLUGS, AND SIMILAR WIRING DEVICES |
C22.2 NO. 269.2-17 | Surge protective devices - Type 2 - Permanently connected |
CSA C22.2 No. 255 : 2004 | NEON TRANSFORMERS AND POWER SUPPLIES |
CSA C22.2 No. 244:2005 | SWITCHBOARDS |
CSA C22.2 No. 27 :2009 | BUSWAYS |
C22.2 NO. 243-17 | Vacuum cleaners, blower cleaners, and household floor finishing machines (Binational standard with UL 1017) |
C22.2 NO. 236-15 | Heating and cooling equipment (Bi-national standard with UL 1995) |
IEEE 45.6-2016 | IEEE Recommended Practice for Electrical Installations on Shipboard--Electrical Testing |
CSA C22.2 NO. 60947-4-2:14 (R2019) | Low-voltage switchgear and controlgear - Part 4-2: Contactors and motor-starters - AC semiconductor motor controllers and starters ( Bi-national standard, with UL 60947-4-2) |
CSA C22.2 No. 61 : 2016 | HOUSEHOLD COOKING RANGES |
CSA C22.2 No. 0.19 :2010 | REQUIREMENTS FOR SERVICE ENTRANCE EQUIPMENT |
CAN/CSA-E61558-1:12 (R2017) | Safety of power transformers, power supplies, reactors and similar products - Part 1: General requirements and tests (Adopted IEC 61558- 1:1997 + A1:1998, edition 2.1, 2009-04 with Canadian deviations) | Sécurité des transformateurs, alimentations, bobines d\'inductance et produits analogues - Partie 1: Exigences générales et essais (norme CEI 61558-1:1997 + A1:1998 adoptée, édition 2.1, 2009-04 avec exigences propres au Canada) |
CSA E61558.1:2012 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
CSA E61558.1 : 2012 : INC : UPD 1 : 2014 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
ASME A17.5 : 2014 | ELEVATOR AND ESCALATOR ELECTRICAL EQUIPMENT |
IEEE C37.14-2015 | IEEE Standard for DC (3200 V and below) Power Circuit Breakers Used in Enclosures |
UL 1699:3ED 2017-05-03 | Arc-Fault Circuit-Interrupters |
CSA C22 NO. 4 : 2016 | ENCLOSED AND DEAD-FRONT SWITCHES |
UL 50:13ED 2015-10-16 | Enclosures for Electrical Equipment, Non-Environmental Considerations |
CSA C22.2 No. 29 : 2015 | PANELBOARDS AND ENCLOSED PANELBOARDS |
CSA C22.2 No. 270 : 2014 | ARC FAULT PROTECTIVE DEVICES |
NFPA 302 : 2010 | PLEASURE AND COMMERCIAL MOTOR CRAFT |
UL 83:16ED 2017-07-28 | Standard for Thermoplastic-Insulated Wires and Cables |
CSA C22.2 No. 144 : 1991 | GROUND FAULT CIRCUIT INTERRUPTERS |
UL 1500:3ED 1997-09-05 | Standard for Ignition-Protection Test for Marine Products |
CSA C22.2 No. 0.2 : 2016 | INSULATION COORDINATION |
UL 943:5ED 2016-05-17 | Ground-Fault Circuit-Interrupters |
CSA C22.2 No. 286 : 2015 | INDUSTRIAL CONTROL PANELS AND ASSEMBLIES |
CSA C22.2 No. 178.1 : 2014 | TRANSFER SWITCH EQUIPMENT |
CSA C22.2 No. 115 : 2014 | METER-MOUNTING DEVICES |
CSA C22.2 No. 65 : 2013 | WIRE CONNECTORS |
IEEE C37.13-2015 | IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
C22.2 NO. 8-13 (R2018) | Electromagnetic interference (EMI) filters |
IEEE C37.09-1999 | IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
C22.2 NO. 75-17 | Thermoplastic insulated wires and cables (Trinational standard with UL 83 and NMX-J-010-ANCE-2017) |
CSA C22.2 No. 14 : 2013 | INDUSTRIAL CONTROL EQUIPMENT |
UL 414:9ED 2016-01-05 | Meter Sockets |
CSA C22.2 NO. 60947-4-1:14 (R2019) | Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters ( Bi-national standard, with UL 60947-4-1) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.