IEEE 1310-2012 REDLINE
Withdrawn
IEEE Recommended Practice for Thermal Cycle Testing of Form-Wound Stator Bars and Coils for Large Rotating Machines
English
05-21-2012
03-30-2023
1. Overview
2. Normative references
3. Definitions
4. Thermal cycling test description
5. Thermal cycling test setup
6. Bar/coil preparation
7. Diagnostic tests preceding and during thermal cycling
8. Post-thermal cycle tests
9. Preparation of test report
Annex A (normative) - Sample calculation for estimating
current rating of test supply
Annex B (informative) - Decisions required by
manufacturer/purchaser/testing facility
Annex C (informative) - Bibliography
Specifies the relative ability of high-voltage form-wound stator bars and coils of large rotating machines to resist deterioration due to rapid heating and cooling resulting from machine load cycling is described.
| Committee |
Electric Machinery
|
| DocumentType |
Standard
|
| ISBN |
978-0-7381-7270-5
|
| Pages |
30
|
| PublisherName |
Institute of Electrical & Electronics Engineers
|
| Status |
Withdrawn
|
| Supersedes |
| IEEE 1665 : 2009 | GUIDE FOR THE REWIND OF SYNCHRONOUS GENERATORS, 50 HZ AND 60 HZ, RATED 1 MVA AND ABOVE |
| (INACTIVE RECORD)IEEE C50.12 : 2005 | SALIENT-POLE 50 HZ AND 60 HZ SYNCHRONOUS GENERATORS AND GENERATOR/MOTORS FOR HYDRAULIC TURBINE APPLICATIONS RATED 5 MVA AND ABOVE |
| IEEE DRAFT C50.12 : D10 2004 | SALIENT-POLE 50 AND 60 HZ SYNCHRONOUS GENERATORS AND GENERATOR/MOTORS FOR HYDRAULIC TURBINE APPLICATIONS RATED 5 MVA AND ABOVE |
| IEEE DRAFT 434 : D10 2006 | FUNCTIONAL EVALUATION OF INSULATION SYSTEMS FOR AC ELECTRIC MACHINES RATED 2300 V AND ABOVE |
| IEEE 434-2006 | IEEE Guide for Functional Evaluation of Insulation Systems for AC Electric Machines Rated 2300 V and Above |
| IEEE C50.13 : 2014 | CYLINDRICAL-ROTOR 50 HZ AND 60 HZ, SYNCHRONOUS GENERATORS RATED 10 MVA AND ABOVE |
| IEEE 434-2006 | IEEE Guide for Functional Evaluation of Insulation Systems for AC Electric Machines Rated 2300 V and Above |
| ASTM D 4496 : 2013 | Standard Test Method for D-C Resistance or Conductance of Moderately Conductive Materials |
| ASTM D 5023 : 2015 : REDLINE | Standard Test Method for Plastics: Dynamic Mechanical Properties: In Flexure (Three-Point Bending) |
| IEC TS 60034-27:2006 | Rotating electrical machines - Part 27: Off-line partial discharge measurements on the stator winding insulation of rotating electrical machines |
| ASTM D 352 : 1997 | Standard Test Methods for Pasted Mica Used in Electrical Insulation |
| ASTM D 5026 : 2015 : REDLINE | Standard Test Method for Plastics: Dynamic Mechanical Properties: In Tension |
| ASTM D 619 : 2014 | Standard Test Methods for Vulcanized Fibre Used for Electrical Insulation |
| IEC TS 60034-18-34:2000 | Rotating electrical machines - Part 18-34: Functional evaluation of insulation systems - Test procedures for form-wound windings - Evaluation of thermomechanical endurance of insulation systems |
| IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
| ASTM D 790 : 2017 : REDLINE | Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials |
| IEEE 1434-2014 | IEEE Guide for the Measurement of Partial Discharges in AC Electric Machinery |
| ASTM D 1868 : 2013 : REDLINE | Standard Test Method for Detection and Measurement of Partial Discharge (Corona) Pulses in Evaluation of Insulation Systems |
| IEEE 286-2000 | IEEE Recommended Practice for Measurement of Power Factor Tip-Up of Electric Machinery Stator Coil Insulation |
| IEEE C50.13 : 2014 | CYLINDRICAL-ROTOR 50 HZ AND 60 HZ, SYNCHRONOUS GENERATORS RATED 10 MVA AND ABOVE |
| ASTM D 494 : 2011 : REDLINE | Standard Test Method for Acetone Extraction of Phenolic Molded or Laminated Products |