ISO 21138-2:2007
Withdrawn
View Superseded by
Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Part 2: Pipes and fittings with smooth external surface, Type A
Hardcopy , PDF
English, French
10-22-2007
04-09-2025
ISO 21138-2:2007, together with ISO 21138-1, specifies the definitions and requirements for pipes with a smooth external surface (Type A), fittings and systems based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping in the field of non-pressure systems for underground drainage and sewerage.
ISO 21138-2:2007 specifically refers to PVC, PP and PE materials
ISO 21138-2:2007 specifies test methods and test parameters.
ISO 21138-2:2007 covers a range of pipe and fitting sizes, materials, pipe constructions, and nominal ring stiffnesses, and gives recommendations concerning colours.
In conjunction with ISO 21138-1, it is applicable to PVC-U, PP and PE structured-wall pipes and fittings, to their joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for the transport of drainage and sewage.
ISO 21138-2:2007 is applicable to PVC-U, PP and PE structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints.
| DevelopmentNote |
DRAFT ISO/DIS 21138-2 is also available for this standard. (06/2017)
|
| DocumentType |
Standard
|
| Pages |
41
|
| PublisherName |
International Organization for Standardization
|
| Status |
Withdrawn
|
| SupersededBy |
| Standards | Relationship |
| NEN ISO 21138-2 : 2008 | Identical |
| ISO 21138-3:2007 | Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Part 3: Pipes and fittings with non-smooth external surface, Type B |
| 06/30136260 DC : DRAFT MAR 2006 | ISO 21138-1 - PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYLCHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 1 - MATERIAL AND PERFORMANCE SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEMS |
| ISO 15398:2012 | Specifications for thermoplastics covers and frames for manholes and inspection chambers used in non-traffic areas |
| 14/30275072 DC : 0 | BS ISO 17902 - WRAPPED ELECTROFOAMING JOINTS FOR PE PIPING SYSTEMS WITH SMOOTH OUTER WALL FOR GRAVITY DRAINS AND SEWERS |
| BS ISO 15398:2012 | Specifications for thermoplastics covers and frames for manholes and inspection chambers used in non-traffic areas |
| ISO 21138-1:2007 | Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Part 1: Material specifications and performance criteria for pipes, fittings and system |
| ISO 13272:2011 | Plastics piping systems for non-pressure underground drainage and sewerage — Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP), polypropylene with mineral modifiers (PP-MD) and polyethylene (PE) — Specifications for manholes and inspection chambers in traffic areas and underground installations |
| 11/30245512 DC : 0 | BS ISO 15398 - SPECIFICATIONS FOR THERMOPLASTICS COVERS AND FRAMES FOR MANHOLES AND INSPECTION CHAMBERS USED IN NON-TRAFFIC AREAS |
| ISO/TS 17902:2016 | Wrapped electrofoaming joints for polyethylene (PE) piping systems with smooth outer wall for gravity drains and sewers |
| EN 1277:2003 | Plastics piping systems - Thermoplastics piping systems for buried non-pressure applications - Test methods for leaktightness of elastomeric sealing ring type joints |
| ISO 580:2005 | Plastics piping and ducting systems — Injection-moulded thermoplastics fittings — Methods for visually assessing the effects of heating |
| ISO 2507-2:1995 | Thermoplastics pipes and fittings — Vicat softening temperature — Part 2: Test conditions for unplasticized poly(vinyl chloride) (PVC-U) or chlorinated poly(vinyl chloride) (PVC-C) pipes and fittings and for high impact resistance poly (vinyl chloride) (PVC-HI) pipes |
| ISO 3451-1:2008 | Plastics — Determination of ash — Part 1: General methods |
| ISO 12091:1995 | Structured-wall thermoplastics pipes — Oven test |
| ISO 8773:2006 | Plastics piping systems for non-pressure underground drainage and sewerage — Polypropylene (PP) |
| ISO 1167-2:2006 | Thermoplastics pipes, fittings and assemblies for the conveyance of fluids — Determination of the resistance to internal pressure — Part 2: Preparation of pipe test pieces |
| ISO 8772:2006 | Plastics piping systems for non-pressure underground drainage and sewerage — Polyethylene (PE) |
| ISO 11173:1994 | Thermoplastics pipes — Determination of resistance to external blows — Staircase method |
| ISO 2507-1:1995 | Thermoplastics pipes and fittings — Vicat softening temperature — Part 1: General test method |
| ISO 21138-3:2007 | Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Part 3: Pipes and fittings with non-smooth external surface, Type B |
| ISO 3127:1994 | Thermoplastics pipes — Determination of resistance to external blows — Round-the-clock method |
| ISO 161-1:1996 | Thermoplastics pipes for the conveyance of fluids — Nominal outside diameters and nominal pressures — Part 1: Metric series |
| PREN 15346 : DRAFT 2013 | PLASTICS - RECYCLED PLASTICS - CHARACTERISATION OF POLY(VINYL CHLORIDE) (PVC) RECYCLATES |
| ISO 527-2:2012 | Plastics — Determination of tensile properties — Part 2: Test conditions for moulding and extrusion plastics |
| ISO 9002:1994 | Quality systems — Model for quality assurance in production, installation and servicing |
| EN 922:1994 | Plastics piping and ducting systems - Pipes and fittings of unplasticized poly(vinyl chloride) (PVC-U) - Specimen preparation for determination of the viscosity number and calculation of the K-value |
| ISO 3126:2005 | Plastics piping systems — Plastics components — Determination of dimensions |
| EN 1979:1999 | Plastics piping and ducting systems - Thermoplastics spirally-formed structured-wall pipes - Determination of the tensile strength of a seam |
| ISO 22088-3:2006 | Plastics — Determination of resistance to environmental stress cracking (ESC) — Part 3: Bent strip method |
| ISO 1183-1:2012 | Plastics — Methods for determining the density of non-cellular plastics — Part 1: Immersion method, liquid pyknometer method and titration method |
| EN 10204:2004 | Metallic products - Types of inspection documents |
| ISO 9001:2015 | Quality management systems — Requirements |
| EN 14741:2006 | Thermoplastics piping and ducting systems - Joints for buried non-pressure applications - Test method for the long-term sealing performance of joints with elastomeric seals by estimating the sealing pressure |
| ISO 11357-6:2008 | Plastics — Differential scanning calorimetry (DSC) — Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) |
| ISO 306:2013 | Plastics — Thermoplastic materials — Determination of Vicat softening temperature (VST) |
| ISO 4435:2003 | Plastics piping systems for non-pressure underground drainage and sewerage — Unplasticized poly(vinyl chloride) (PVC-U) |
| ISO 9967:2016 | Thermoplastics pipes — Determination of creep ratio |
| EN 1905:1998 | Plastics piping systems - Unplasticized poly(vinyl chloride) (PVC-U) pipes, fittings and material - Method for assessment of the PVC content based on total chlorine content |
| EN 1053:1995 | Plastics piping systems - Thermoplastics piping systems for non-pressure applications - Test method for watertightness |
| ISO 21138-1:2007 | Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Part 1: Material specifications and performance criteria for pipes, fittings and system |
| ISO 178:2010 | Plastics — Determination of flexural properties |
| ISO 9969:2016 | Thermoplastics pipes — Determination of ring stiffness |
| EN 1437:2002 | Plastics piping systems - Piping systems for underground drainage and sewerage - Test method for resistance to combined temperature cycling and external loading |
| ISO 1133:2005 | Plastics — Determination of the melt mass-flow rate (MFR) and the melt volume-flow rate (MVR) of thermoplastics |
| EN 12099:1997 | Plastics piping systems - Polyethylene piping materials and components - Determination of volatile content |
| ISO 9852:2007 | Unplasticized poly(vinyl chloride) (PVC-U) pipes — Dichloromethane resistance at specified temperature (DCMT) — Test method |
| ISO 1167-1:2006 | Thermoplastics pipes, fittings and assemblies for the conveyance of fluids — Determination of the resistance to internal pressure — Part 1: General method |
| ISO 2505:2005 | Thermoplastics pipes — Longitudinal reversion — Test method and parameters |
| EN 1446 : 1996 | PLASTICS PIPING AND DUCTING SYSTEMS - THERMOPLASTICS PIPES - DETERMINATION OF RING FLEXIBILITY |