I.S. EN 50174-3:2013
Current
The latest, up-to-date edition.
INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
Hardcopy , PDF
English
01-01-2013
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
National Foreword
Foreword
Introduction
1 Scope and conformance
2 Normative references
3 Terms, definitions and abbreviations
4 Requirements for planning installations of
information technology cabling
5 Requirements for the installation of
information technology cabling
6 Segregation
7 Additional installation practices for
specific sites and services
Annex A (informative) - EMC and protection
Annex B (informative) - Earth potential rise (EPR)
Annex C (informative) - Application of responsibilities
Annex D (informative) - A-deviations
Bibliography
Describes requirements and gives recommendations for the following aspects of information technology cabling: a) planning; b) installation practice.
DocumentType |
Standard
|
Pages |
120
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
BS EN 50174-3 : 2013 | Identical |
UNE-EN 50174-3:2005 | Identical |
EN 50174-3:2013/A1:2017 | Identical |
NBN EN 50174-3 : 2013 | Identical |
NEN EN 50174-3 : 2013 AMD 1 2017 | Identical |
DIN EN 50174-3 : 2017 | Identical |
SN EN 50174-3 : 2013 AMD 1 2017 | Identical |
NF EN 50174-3 : 2014 AMD 1 2017 | Identical |
IEC 61537:2006 | Cable management - Cable tray systems and cable ladder systems |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
EN 60794-3-10:2015 | Optical fibre cables - Part 3-10: Outdoor cables - Family specification for duct, directly buried or lashed aerial optical telecommunication cables |
IEC TR 61000-5-3:1999 | Electromagnetic compatibility (EMC) - Part 5-3: Installation and mitigation guidelines - HEMP protection concepts |
IEC 60364-5-534:1997 | Electrical installations of buildings - Part 5: Selection and erection of electrical equipment - Section 534: Devices for protection against overvoltages |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC 60794-3:2014 | Optical fibre cables - Part 3: Outdoor cables - Sectional specification |
IEC 60825-2:2004+AMD1:2006+AMD2:2010 CSV | Safety of laser products - Part 2: Safety of optical fibre communication systems (OFCS) |
EN 50411-2-9:2010 | Fibre organisers and closures to be used in optical fibre communications systems - Product specifications - Part 2-9: Non-sealed closures for air blown fibre microduct cable, for category S & A |
PREN 50700 : DRAFT 2012 | INFORMATION TECHNOLOGY - PREMISES DISTRIBUTION ACCESS NETWORK (PDAN) CABLING TO SUPPORT DEPLOYMENT OF OPTICAL BROADBAND NETWORKS |
IEC 61663-1:1999 | Lightning protection - Telecommunication lines - Part 1: Fibre optic installations |
EN 60794-3-20:2016 | Optical fibre cables - Part 3-20: Outdoor cables - Family specification for self-supporting aerial telecommunication cables |
EN 62368-1:2014/AC:2017-03 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS (IEC 62368-1:2014, MODIFIED) |
EN 60794-3-40:2008 | Optical fibre cables - Part 3-40: Outdoor cables - Family specification for sewer cables and conduits for installation by blowing and/or pulling in non-man accessible storm and sanitary sewers |
IEC 60794-3-40:2008 | Optical fibre cables - Part 3-40: Outdoor cables - Family specification for sewer cables and conduits for installation by blowing and/or pulling in non-man accessible storm and sanitary sewers |
EN 50174-1:2009/A2:2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
EN 61969-1:2012 | Mechanical structures for electronic equipment - Outdoor enclosures - Part 1: Design guidelines |
IEC 61969-1:2011 | Mechanical structures for electronic equipment - Outdoor enclosures - Part 1: Design guidelines |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
IEC 60794-3-12:2012 | Optical fibre cables - Part 3-12: Outdoor cables - Detailed specification for duct and directly buried optical telecommunication cables for use in premises cabling |
IEC 60079-17:2013 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
EN 50411-2-5:2009 | Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2-5: Sealed closures for air blown fibre microduct, type 1, for category S & A |
EN 60794-3:2015 | Optical fibre cables - Part 3: Sectional specification - Outdoor cables |
IEC 60794-1-2:2017 | Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures - General guidance |
HD 60364-5-54:2011/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
EN 13501-6:2014 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES |
EN 12613:2009 | Plastics warning devices for underground cables and pipelines with visual characteristics |
IEC 61663-2:2001 | Lightning protection - Telecommunication lines - Part 2: Lines using metallic conductors |
IEC 60794-3-10:2015 | Optical fibre cables - Part 3-10: Outdoor cables - Family specification for duct, directly buried and lashed aerial optical telecommunication cables |
EN 60794-3-50 : 2008 | OPTICAL FIBRE CABLES - PART 3-50: OUTDOOR CABLES - FAMILY SPECIFICATION FOR GAS PIPE CABLES AND SUBDUCTS FOR INSTALLATION BY BLOWING AND/OR PULLING/DRAGGING IN GAS PIPES |
IEC 60794-3-11:2010 | Optical fibre cables - Part 3-11: Outdoor cables - Product specification for duct, directly buried, and lashed aerial single-mode optical fibre telecommunication cables |
HD 637 S1:1999/corrigendum:2005 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. |
EN 60794-3-12:2013 | Optical fibre cables - Part 3-12: Outdoor cables - Detailed specification for duct and directly buried optical telecommunication cables for use in premises cabling |
EN 60794-5-10:2014 | Optical fibre cables - Part 5–10: Family specification - Outdoor microduct optical fibre cables, microducts and protected microducts for installation by blowing |
EN 61663-2 : 2001 | LIGHTNING PROTECTION - TELECOMMUNICATION LINES - PART 2: LINES USING METALLIC CONDUCTORS |
IEC 61969-2:2011 | Mechanical structures for electronic equipment - Outdoor enclosures - Part 2: Coordination dimensions |
EN 50700:2014 | Information technology - Premises distribution access network (PDAN) cabling to support deployment of optical broadband networks |
EN 50173-3 : 2007 COR 2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 3: INDUSTRIAL PREMISES |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
EN 61663-1 : 1999 | LIGHTNING PROTECTION - TELECOMMUNICATION LINES - PART 1 - FIBRE OPTIC INSTALLATIONS |
EN 61386-1:2008 | Conduit systems for cable management - Part 1: General requirements |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
HD 60364-4-444:2010/AC:2012 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-444: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES |
EN 50173-1:2011 | Information technology - Generic cabling systems - Part 1: General requirements |
EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 50085-1 : 2005 AMD 1 2013 | CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS - PART 1: GENERAL REQUIREMENTS |
HD 60364-5-534:2016 | Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control - Clause 534: Devices for protection against transient overvoltages |
IEC 60364-4-444:1996 | Electrical installations of buildings - Part 4: Protection for safety - Section 444: Protection against electromagnetic interferences (EMI) in installations of buildings |
EN 50174-2 : 2009 AMD 2 2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
IEC 60794-3-30:2008 | Optical fibre cables - Part 3-30: Outdoor cables - Family specification for optical telecommunication cables for lakes, river crossings and coastal application |
EN 60794-3-11:2010 | Optical fibre cables - Part 3-11: Outdoor cables - Product specification for duct, directly buried and lashed aerial single-mode optical fibre telecommunication cables |
EN 60794-4-20:2012 | OPTICAL FIBRE CABLES - PART 4-20: AERIAL OPTICAL CABLES ALONG ELECTRICAL POWER LINES - FAMILY SPECIFICATION FOR ADSS (ALL DIELECTRIC SELF SUPPORTED) OPTICAL CABLES (IEC 60794-4-20:2012) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 60794-3-60:2008 | Optical fibre cables - Part 3-60: Outdoor cables - Family specification for drinking water pipe cables and subducts for installation by blowing and/or pulling/dragging/floating in drinking water pipes |
EN 50341-1:2012 | Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications |
IEC 60794-3-21:2015 | Optical fibre cables - Part 3-21: Outdoor cables - Product specification for optical self-supporting aerial telecommunication cables for use in premises cabling |
IEC 60794-3-60:2008 | Optical fibre cables - Part 3-60: Outdoor cables - Family specification for drinking water pipe cables and subducts for installation by blowing and/or pulling/dragging/floating in drinking water pipes |
IEC 60794-5-10:2014 | Optical fibre cables - Part 5-10: Family specification - Outdoor microduct optical fibre cables, microducts and protected microducts for installation by blowing |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
EN 124:1994 | Gully tops and manhole tops for vehicular and pedestrian areas - Design requirements, type testing, marking, quality control |
EN 61969-2:2012 | Mechanical structures for electronic equipment - Outdoor enclosures - Part 2: Coordination dimensions |
EN 50411-2-4:2012 | Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2-4: Sealed dome fibre splice closures Type 1, for category S & A |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
EN 61300-3-35:2015 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-35: Examinations and measurements - Visual inspection of fibre optic connectors and fibre-stub transceivers |
EN 60794-5-20 : 2014 | Optical fibre cables - Part 5-20: Family specification - Outdoor microduct fibre units, microducts and protected microducts for installation by blowing |
IEC 60794-5-20:2014 | Optical fibre cables - Part 5-20: Family specification - Outdoor microduct fibre units, microducts and protected microducts for installation by blowing |
EN 60794-1-2:2017/AC:2017-07 | OPTICAL FIBRE CABLES - PART 1-2: GENERIC SPECIFICATION - BASIC OPTICAL CABLE TEST PROCEDURES - GENERAL GUIDANCE (IEC 60794-1-2:2017) |
EN 60794-3-21:2016 | Optical fibre cables - Part 3-21: Outdoor cables - Product specification for optical self-supporting aerial telecommunication cables for use in premises cabling |
IEC 60794-3-50:2008 | Optical fibre cables - Part 3-50: Outdoor cables - Family specification for gas pipe cables and subducts for installation by blowing and/or pulling/dragging in gas pipes |
EN 60079-14:2014/AC:2016 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016) |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 61386-1:2008+AMD1:2017 CSV | Conduit systems for cable management - Part 1: General requirements |
EN 60794-3-30:2008 | OPTICAL FIBRE CABLES - PART 3-30: OUTDOOR CABLES - FAMILY SPECIFICATION FOR OPTICAL TELECOMMUNICATION CABLES FOR LAKES, RIVER CROSSINGS AND COASTAL APPLICATION |
EN 60079-17:2014 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
IEC 60794-3-20:2016 | Optical fibre cables - Part 3-20: Outdoor cables - Family specification for self-supporting aerial telecommunication cables |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 60825-2:2004/A2:2010 | SAFETY OF LASER PRODUCTS - PART 2: SAFETY OF OPTICAL FIBRE COMMUNICATION SYSTEMS (OFCS) |
EN 61537:2007 | Cable management - Cable tray systems and cable ladder systems |
CLC/TR 50173-99-2:2010 | Information technology - Implementation of BCT applications using cabling in accordance with EN 50173-4 |
EN 50173-5 : 2007 AMD 2 2012 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 5: DATA CENTRES |
EN 50173-4 : 2007 AMD 2 2012 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 4: HOMES |
EN 50310:2016 | Telecommunications bonding networks for buildings and other structures |
EN 50411-2-2:2012 | Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2-2: Sealed pan fibre splice closures Type 1, for category S & A |
EN 50173-6:2013 | Information technology - Generic cabling systems - Part 6: Distributed building services |
IEC 62368-1:2014 | Audio/video, information and communication technology equipment - Part 1: Safety requirements |
EN 50411-2-3:2012 | Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2-3: Sealed inline fibre splice closures Type 1, for category S & A |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-