Introduction
1 Scope
2 Normative references
3 Terms and definitions and abbreviations
4 Design responsibilities
5 Effective anchorages for buildings of Consequence
   Class 2a
6 Assignment of temperate hardwoods to BS EN 338
   strength classes [BS EN 1995-1-1:2004+A1:2008, 3.2]
7 Horizontally glued laminated hardwood members
   [BS EN 1995-1-1:2004+A1:2008, 3.3]
8 Factor, k[c,90,] for compression perpendicular to
   grain [BS EN 1995-1-1:2004+A1:2008, 6.1.5]
9 Effective lengths of compression members
   [BS EN 1995-1-1:2004+A1:2008, 6.3.2]
10 Limits on notches and circular holes in joists for
   which no calculations are required
   [BS EN 1995-1-1:2004+A1:2008, 6.5.1]
11 Beams with circular holes
12 Yield moment of annular ring-shanked nails
   [BS EN 1995-1-1:2004+A1:2008, 8.3.1.1(4)]
13 Diameters for evaluating lateral load-carrying
   capacities of screws [BS EN 1995-1-1:2004+A1:2008,
   8.7.1]
14 Axially loaded screws [BS EN 1995-1-1:2004+A1:2008,
   8.7.2]
15 Connections made with punched metal plate fastener
   joints [BS EN 1995-1-1:2004+A1:2008, 8.8.1]
16 Misalignment tolerances in punched metal plate
   fastener joints [BS EN 1995-1-1:2004+A1:2008, 8.8.5.1]
17 Contact pressure between timber members in punched
   metal plate fastener joints under compression
   [BS EN 1995-1-1:2004+A1:2008, 8.8.5.1(3)]
18 Trusses with punched metal plate fasteners
   [BS EN 1995-1-1:2004+A1:2008, 9.2.2]
19 Masonry shielding to wall diaphragms
20 Simplified analysis of wall diaphragms
   [BS EN 1995-1-1:2004+A1:2008, 9.2.4.3]
21 Contribution of plasterboard to racking resistance
22 Evaluation of design racking resistance of
   plasterboard-clad timber frame walls
23 Bracing to trussed rafter roofs
   [BS EN 1995-1-1:2004+A1:2008, 9.2.5.3]
24 Lateral load-carrying capacity of glued lap joints
   [BS EN 1995-1-1:2004+A1:2008, 10.3]
Annexes
Annex A (normative) - Exchange of information
        between building designer and component
        designer(s)
Annex B (informative) - Effective anchorage of floors
        to timber frame wall buildings of Consequence
        Class 2a
Annex C (informative) - Actions and combinations of
        actions that may be considered in the design
        of trussed rafters
Annex D (informative) - Masonry shielding to timber
        frame wall diaphragms
Annex E (normative) - Bracing of trussed rafter roofs
Annex F (informative) - Optional recommendations for
        the support of water tanks in trussed rafter
        roofs
Bibliography

PD 6693-1

Committee
B/525/5
DocumentType
Draft
Pages
66
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

BS EN 1075:2014 Timber structures. Test methods. Joints made with punched metal plate fasteners
BS EN 772-7:1998 Methods of test for masonry units Determination of water absorption of clay masonry damp proof course units by boiling in water
BS EN 1995-1-1 NA : 2004 UK NATIONAL ANNEX TO EUROCODE 5: DESIGN OF TIMBER STRUCTURES - PART 1-1: GENERAL - COMMON RULES AND RULES FOR BUILDINGS
BS EN 386:2001 Glued laminated timber. Performance requirements and minimum production requirements
BS EN 520 : 2004 GYPSUM PLASTERBOARDS - DEFINITIONS, REQUIREMENTS AND TEST METHODS
BS EN 14592 : 2008 TIMBER STRUCTURES - DOWEL-TYPE FASTENERS - REQUIREMENTS
BS EN 1991-1-7 : 2006 EUROCODE 1 - ACTIONS ON STRUCTURES - PART 1-7: GENERAL ACTIONS - ACCIDENTAL ACTIONS
BS EN 1991-1-7 NA : 2006 NATIONAL ANNEX TO EUROCODE 1: ACTIONS ON STRUCTURES - PART 1-7: ACCIDENTAL ACTIONS
BS EN 1991-1-1:2002 Eurocode 1. Actions on structures General actions - Densities, self-weight, imposed loads for buildings
BS EN 338:2016 Structural timber. Strength classes
BS EN 1990 NA : 2002 + A1 : 2005 UK NATIONAL ANNEX FOR EUROCODE - BASIS OF STRUCTURAL DESIGN
BS EN 1991-1-4 : 2005 EUROCODE 1: ACTIONS ON STRUCTURES - PART 1-4: GENERAL ACTIONS - WIND ACTIONS
BS EN 14250:2010 Timber structures. Product requirements for prefabricated structural members assembled with punched metal plate fasteners
BS EN 15425:2017 Adhesives. One component polyurethane (PUR) for load-bearing timber structures. Classification and performance requirements
PD 6697:2010 Recommendations for the design of masonry structures to BS EN 1996-1-1 and BS EN 1996-2
BS EN 13986 : 2004 WOOD-BASED PANELS FOR USE IN CONSTRUCTION - CHARACTERISTICS, EVALUATION OF CONFORMITY AND MARKING
BS EN 301:2013 Adhesives, phenolic and aminoplastic, for load-bearing timber structures. Classification and performance requirements
BS 8103-1:2011 Structural design of low-rise buildings Code of practice for stability, site investigation, foundations, precast concrete floors and ground floor slabs for housing
BS EN 1996-1-1 : 2005 EUROCODE 6 - DESIGN OF MASONRY STRUCTURES - PART 1-1: GENERAL RULES FOR REINFORCED AND UNREINFORCED MASONRY STRUCTURES
BS EN 1995-1-1 : 2012 EUROCODE 5: DESIGN OF TIMBER STRUCTURES - PART 1-1: GENERAL - COMMON RULES AND RULES FOR BUILDINGS
BS EN 771-1 : 2011 SPECIFICATION FOR MASONRY UNITS - PART 1: CLAY MASONRY UNITS

£20.00