• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Meet Inform Select. Always-on access to the Standards your organisation relies on. Explore Inform Select

12/30259213 DC : 0

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

BS EN 14181 - STATIONARY SOURCE EMISSIONS - QUALITY ASSURANCE OF AUTOMATED MEASURING SYSTEMS

Available format(s)

Hardcopy , PDF

Language(s)

English

Superseded date

30-11-2014

Superseded by

BS EN 14181:2014

£20.00
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Principle
6 Calibration and validation of the AMS
  (QAL2)
7 Ongoing quality assurance during operation
  (QAL3)
8 Annual Surveillance Test (AST)
9 Documentation
Annex A (normative) - QAL2 and AST functional test
        of AMS
Annex B (normative) - Test of linearity
Annex C (informative) - Control Charts
Annex D (informative) - Documentation
Annex E (informative) - Example of calculation of the
        calibration function and of the variability test
Annex F (informative) - Example of calculation of the
        standard deviation s[AMS] of the AMS at zero
        and span level
Annex G (informative) - Example of using the calibration
        function and the variability test in the AST
Annex H (informative) - CUSUM charts field form (drift)
Annex I (informative) - Implementation of QAL1
Annex J (normative) - k[v] and t[0,95] values
Annex K (informative) - Significant technical changes
Bibliography

BS EN 14181

Committee
EH/2/1
DocumentType
Draft
Pages
85
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

Standards Relationship
PREN 14181 : DRAFT 2012 Identical

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
EN 15267-3:2007 Air quality - Certification of automated measuring systems - Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources
CEN/TR 15983:2010 Stationary source emissions - Guidance on the application of EN 14181:2004
ISO 14956:2002 Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
EN 15267-2:2009 Air quality - Certification of automated measuring systems - Part 2: Initial assessment of the AMS manufacturer’s quality management system and post certification surveillance for the manufacturing process
ISO 11095:1996 Linear calibration using reference materials
EN 15259:2007 Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
EN 13284-1:2017 Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN 13284-2:2017 Stationary source emissions - Determination of low range mass concentration of dust - Part 2: Quality assurance of automated measuring systems
EN ISO 14956:2002 Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002)
ENV 13005 : DRAFT 1999 GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
EN 14385:2004 Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI and V
EN 14792:2017 Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: chemiluminescence
EN 15267-1:2009 Air quality - Certification of automated measuring systems - Part 1: General principles
ISO 3534-1:2006 Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability

£20.00