• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Meet Inform Select. Always-on access to the Standards your organisation relies on. Explore Inform Select

AS/NZS 3112:1993

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Approval and test specification - Plugs and socket-outlets

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

13-09-1993

Superseded date

29-05-2024

Superseded by

AS/NZS 3112:2000

£67.62
Excluding VAT

1 - AS/NZS 3112:1993 APPROVAL AND TEST SPECIFICATION-PLUGS AND SOCKET-OUTLETS
4 - PREFACE
5 - CONTENTS
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 APPLICATION
7 - 1.2.1 General requirements of AS 3100
7 - 1.2.2 Specific requirements of this Standard
7 - 1.3 REFERENCED DOCUMENTS
8 - 1.4 DEFINITIONS
8 - 1.4.1 Non-rewirable plug
8 - 1.4.2 Plug
8 - 1.4.3 Rewirable plug
8 - 1.4.4 Socket-outlet
8 - 1.4.5 Fully recessed socket-outlet
9 - SECTION 2 PLUGS
9 - 2.1 TERMINALS AND INTERNAL CONNECTIONS
9 - 2.1.1 Materials
9 - 2.1.2 Construction of terminals
9 - 2.2 PLUG PINS
9 - 2.2.1 Materials
9 - 2.2.2 Assembly of pins
9 - 2.2.3 Form of pin
9 - 2.3 INSULATING MATERIALS
9 - 2.3.1 General
10 - 2.3.2 Plug body
10 - 2.3.3 Plug cover
10 - 2.4 NON-REWIRABLE PLUGS
10 - 2.5 MEANS OF ENTRY AND CORD ANCHORAGE FOR FLEXIBLE CORD
10 - 2.5.1 General
11 - 2.5.2 Side-entry (of the flexible cord) plugs
11 - 2.6 RADIO INTERFERENCE SUPPRESSION DEVICES
11 - 2.7 FINGER-GRIP
11 - 2.8 RATINGS AND DIMENSIONS OF LOW VOLTAGE PLUGS
11 - 2.8.1 General
12 - 2.8.2 Integrally moulded plug and cord
12 - 2.8.3 Two-pin flat-pin plugs with non-parallel pins
12 - 2.8.4 Compliance with dimensional requirements of Figure2.1
12 - 2.9 INTERNAL CONNECTIONS
12 - 2.10 ARRANGEMENT OF EARTHING CONNECTIONS
12 - 2.11 FUSES
12 - 2.12 MARKING
12 - 2.12.1 Required marking
17 - 2.12.2 Location of marking
17 - 2.12.3 Additional requirements for rewirable plugs
17 - 2.12.4 Earthing connections
17 - 2.12.5 Live connections
17 - 2.12.6 Configuration of plugs
17 - 2.13 DUST PROOF PLUGS
17 - 2.14 TESTS ON PLUGS
17 - 2.14.1 General
18 - 2.14.2 Tumbling barrel test
19 - 2.14.3 Insulation resistance test
19 - 2.14.4 High voltage test
19 - 2.14.5 Flexible cord anchorage test
20 - 2.14.6 Securement of pins
21 - 2.14.7 Attachment of covers
21 - 2.14.8 Additional tests on non-rewirable plug and flexible cord
23 - 2.14.9 Determination of ignitability and combustion propagation
25 - SECTION 3 SOCKET-OUTLETS
25 - 3.1 TERMINALS AND INTERNAL CONNECTIONS
25 - 3.1.1 Material
25 - 3.1.2 Construction of terminals
25 - 3.2 PROHIBITED ARRANGEMENTS
25 - 3.3 SOCKET-OUTLET CONTACTS
25 - 3.3.1 Material
25 - 3.3.2 Construction
25 - 3.3.3 Entry or withdrawal of plug pins into a socket-outlet
25 - 3.3.4 Depth of contact
27 - 3.4 INSULATING MATERIALS
28 - 3.5 RADIO INTERFERENCE SUPPRESSORS
28 - 3.6 DIMENSIONS
28 - 3.6.1 Pin entry apertures for plugs
29 - 3.6.2 Spacing of socket-outlets
29 - 3.6.3 Socket-outlet face plate
30 - 3.6.4 Fully recessed socket-outlets
31 - 3.7 ARRANGEMENT OF EARTHING CONNECTIONS
31 - 3.8 PREVENTION OF CONTACT WITH LIVE PINS
31 - 3.8.1 During normal insertion
32 - 3.8.2 During other than normal insertion
32 - 3.8.3 Alignment of covers
32 - 3.9 FUSES
32 - 3.10 FLOOR SOCKET-OUTLETS
32 - 3.11 SWITCHED SOCKET-OUTLETS
32 - 3.11.1 Socket-outlets switched by insertion of plug pins
33 - 3.11.2 Socket-outlet switches
33 - 3.12 SHUTTERED SOCKET-OUTLETS
33 - 3.13 MARKING
33 - 3.13.1 Required marking
33 - 3.13.2 Location of marking
33 - 3.13.3 Earthing connections
34 - 3.13.4 Live connections
34 - 3.14 DUSTPROOF SOCKET-OUTLETS
34 - 3.15 TESTS FOR SOCKET-OUTLETS
34 - 3.15.1 General
34 - 3.15.2 Insulation resistance test No. 1
35 - 3.15.3 High voltage test
35 - 3.15.4 Current breaking test
36 - 3.15.5 Test of temperature rise
36 - 3.15.6 Insulation resistance test No.2
36 - 3.15.7 Test of earthing connection
37 - 3.15.8 Withdrawal force test
37 - 3.15.9 Determination of ignitability and combustion propagation
38 - APPENDIX A - GAUGE FOR THREE-PIN FLAT-PIN PLUGS
39 - APPENDIX B - GAUGE FOR TWO-PIN FLAT-PIN PLUGS WITH PARALLEL PINS
40 - APPENDIX C - THREE-PIN TEST PLUG FOR FINGER TEST
41 - APPENDIX D - THREE-PIN TEST PLUG FOR INSERTION TEST
42 - APPENDIX E - PLUGS AND SOCKET-OUTLETS FOR USE IN EXTRA-LOW VOLTAGE CIRCUITS
42 - E1 GENERAL
42 - E2 DIMENSIONS AND RATING OF FLAT-PIN PLUGS
43 - APPENDIX F - GAUGE FOR FLAT-AND ROUND-PIN PLUGS
44 - APPENDIX G - THREE-PIN TEST PLUG WITH FLAT-AND ROUND-PINS FOR FINGER TEST

Specifies essential safety requirements for plugs and socket-outlets for approval and test purposes. It is intended to be read in conjunction with AS 3100.

Committee
EL-004
DocumentType
Standard
ISBN
0 7262 8329 0
Pages
38
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Standard specifies essential safety requirements for plugs and socket-outlets, as defined in Clause 1.4, intended for use at extra-low or low voltages and a rated current not exceeding 32A for household or similar purposes. (For extra-low voltage plugs and socket-outlets, see Appendix E.)This Standard does not apply to the following:(a) Appliance couplers for household and similar general purposes (see AS 3109.1).(b) Plugs and socket-outlets for use in installation wiring systems (see AS 3131, NZS/AS 3131).(c) Plugs, socket-outlets and couplers for general industrial applications (see AS 3123).

First published in Australia as AS C112-1937.
Second edition 1940.
Third edition 1951.
Fourth edition 1958.
Fifth edition 1964.
Revised and redesignated AS 3112-1981.
Second edition 1987.
Third edition 1990.
First published in New Zealand as part of NZSS 198-1939.
Second edition 1951.
Third edition 1958.
Fourth edition 1967.
NZSS 2147 first published 1967.
NZSS 198-1967 and NZSS 2147-1967 revised, amalgamated and redesignated in part as NZS 6216:1989.
AS 3112-1990 and NZS 6216:1989 jointly revised and designated Joint Standard AS/NZS 3112:1993.

AS 3109.1-1987 Approval and test specification - Appliance couplers for household and similar general purposes General requirements
AS 2420-1987 Fire test methods for solid insulating materials and non-metallic enclosures used in electrical equipment
AS 3100-1990 Approval and test specification - General requirements for electrical equipment
AS 3000-1986 Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules)
AS 2005.30-1991 Low voltage fuses - Fuses with enclosed fuse-links Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications)
AS 3145-1979 Approval and test specification for radio interference suppression devices
AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
AS 2005.1-1981 Fuses with enclosed fuse-links (up to and including 1000 V a.c. and 1500 V d.c.) - General requirements
AS 3123-1987 Approval and test specification - Plugs, socket-outlets and couplers for general industrial application

AS/NZS 3100:1997 Approval and test specification - General requirements for electrical equipment
AS 3300-1996 Approval and test specification - General requirements for household and similar electrical appliances
AS/NZS 3108:1994 Approval and test specification - Particular requirements for isolating transformers and safety isolating transformers
AS/NZS 3109.1:1996 Approval and test specification - Appliance couplers for household and similar general purposes General requirements
AS 2381.10-1995 Electrical equipment for explosive atmospheres - Selection, installation and maintenance - Equipment in combustible dust (Class II) areas
AS/NZS 3131:1995 Approval and test specification - Plugs and socket-outlets for use in installation wiring systems
AS/NZS 3175.2.2:1994 Approval and test specification - Residual current-operated circuit breakers without integral overcurrent protection for household and similar uses (RCCB’s) Functionally dependent on line voltage
AS/NZS 60598.2.20:1998 Luminaires Particular requirements - Lighting chains
AS/NZS 3018:1997 Electrical installations - Domestic installations
AS/NZS 3003:1999 Electrical installations - Patient treatment areas of hospitals and medical and dental practices
AS/NZS 3350.2.6:1998 Safety of household and similar electrical appliances Particular requirements - Stationary cooking ranges, hobs, ovens and similar appliances
AS/NZS 3194:1993 Approval and test specification - Electric shaver supply units
AS/NZS 3172:1996 Approval and test specification - Electric cooking appliances for household use
AS/NZS 61009.1:1999 Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules
AS/NZS 3175.1:1994 Approval and test specification - Residual current-operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB’s) General rules
AS/NZS 3123:1994 Approval and test specification - Plugs, socket-outlets and couplers for general industrial application
AS/NZS 3175.2.1:1994 Approval and test specification - Residual current-operated circuit breakers without integral overcurrent protection for household and similar uses (RCCB’s) Functionally independent of line voltage
AS/NZS 3105:1998 Approval and test specification - Electrical portable outlet devices
AS/NZS 3250:1995 Approval and test specification - Mains operated electronic and related equipment for household and similar general use
AS 3193-1995 Approval and test specification - Transformer type battery chargers
AS/NZS 3160:1996 Approval and test specification - Hand-held portable electric tools
AS/NZS 2394:1994 Conditioning equipment for the treatment of nocturnal enuresis (bedwetting)
AS/NZS 3156:1995 Approval and test specification - Electric lawnmowers
AS/NZS 7450.1:1999 Safety of hand-held motor-operated electric tools General requirements
AS/NZS 3164:1994 Approval and test specification - Safety of electrically heated blankets, pads and similar flexible heating appliances for household use
AS 3100-1994 Approval and test specification - General requirements for electrical equipment
AS/NZS 60598.1:1998 Luminaires General requirements and tests
AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 3190-1994 Approval and test specification - Residual current devices (current-operated earth-leakage devices)
AS/NZS 3120:1999 Approval and test specification - Cord extension sockets

£67.62