• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Meet Inform Select. Always-on access to the Standards your organisation relies on. Explore Inform Select

AS/NZS 3112:2000

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Approval and test specification - Plugs and socket-outlets

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

03-04-2000

Superseded date

29-05-2024

Superseded by

AS/NZS 3112:2004

£80.60
Excluding VAT

1 - AS/NZS 3112:2000 APPROVAL AND TEST SPECIFICATION-PLUGS AND SOCKET-OUTLETS
4 - PREFACE
5 - CONTENTS
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 APPLICATION
7 - 1.2.1 General requirements of AS/NZS 3100
7 - 1.2.2 Specific requirements of this Standard
7 - 1.3 REFERENCED DOCUMENTS
8 - 1.4 DEFINITIONS
8 - 1.4.1 Fully recessed socket-outlet
9 - 1.4.2 Insulated pin plug
9 - 1.4.3 Non-rewireable plug
9 - 1.4.4 Plug
9 - 1.4.5 Plug, IP-rated, with threaded retaining device
9 - 1.4.6 Rewireable plug
9 - 1.4.7 Socket-outlet
9 - 1.4.8 Socket-outlet, IP-rated, with threaded retaining device
10 - SECTION 2 PLUGS
10 - 2.1 TERMINALS AND INTERNAL CONNECTIONS
10 - 2.1.1 Materials
10 - 2.1.2 Construction of terminals
10 - 2.2 PLUG PINS
10 - 2.2.1 Material for pins
10 - 2.2.2 Assembly of pins
11 - 2.2.3 Form of pin
11 - 2.2.4 Insulation of plug pins
11 - 2.3 INSULATING MATERIALS
11 - 2.3.1 General
11 - 2.3.2 Plug body
12 - 2.3.3 Plug cover
12 - 2.4 NON-REWIREABLE PLUGS
12 - 2.5 MEANS OF ENTRY AND CORD ANCHORAGE FOR FLEXIBLE CORD
12 - 2.5.1 General
12 - 2.5.2 Side-entry (of the flexible cord) plugs
13 - 2.6 RADIO INTERFERENCE SUPPRESSION DEVICES
13 - 2.7 FINGER-GRIP
13 - 2.8 RATINGS AND DIMENSIONS OF LOW VOLTAGE PLUGS
13 - 2.8.1 General
14 - 2.8.2 Integrally moulded plug and cord
14 - 2.8.3 Two-pin flat-pin plugs with non-parallel pins
14 - 2.8.4 Compliance with dimensional requirements of Figure 2.1
14 - 2.8.5 Plugs, IP-rated, with threaded retaining device
14 - 2.9 INTERNAL CONNECTIONS
15 - 2.10 ARRANGEMENT OF EARTHING CONNECTIONS
15 - 2.11 FUSES
15 - 2.12 MARKING
15 - 2.12.1 Required marking
15 - 2.12.2 Location of marking
15 - 2.12.3 Additional requirements for rewireable plugs
15 - 2.12.4 Earthing connections
16 - 2.12.5 Live connections
16 - 2.12.6 Configuration of plugs
16 - 2.13 TESTS ON PLUGS
16 - 2.13.1 General
16 - 2.13.2 Insulation resistance test
18 - 2.13.3 High voltage test
18 - 2.13.4 Flexible cord anchorage test
19 - 2.13.5 Test of external nut or clamping ring
19 - 2.13.6 Attachment of covers
20 - 2.13.7 Tumbling barrel test
20 - 2.13.8 Temperature rise test
21 - 2.13.9 Securement of pins
22 - 2.13.10 Determination of IP rating
22 - 2.13.11 Determination of ignitability and combustion propagation
22 - 2.13.12 Tests on non-rewirable plug and flexible cord
24 - 2.13.13 Tests on the insulation material of insulated pin plugs
36 - SECTION 3 SOCKET-OUTLETS
36 - 3.1 TERMINALS AND INTERNAL CONNECTIONS
36 - 3.1.1 Material
36 - 3.1.2 Construction of terminals
36 - 3.2 PROHIBITED ARRANGEMENTS
36 - 3.3 SOCKET-OUTLET CONTACTS
36 - 3.3.1 Material
36 - 3.3.2 Construction
36 - 3.3.3 Entry or withdrawal of plug pins into a socket-outlet
37 - 3.3.4 Depth of contact
37 - 3.4 INSULATING MATERIALS
38 - 3.5 RADIO INTERFERENCE SUPPRESSORS
38 - 3.6 DIMENSIONS
38 - 3.6.1 Pin entry apertures for plugs
38 - 3.6.2 Spacing of socket-outlets
39 - 3.6.3 Socket-outlet faceplate
39 - 3.6.4 Fully recessed socket-outlets
39 - 3.6.5 Socket, IP-rated, with threaded retaining device*
39 - 3.7 ARRANGEMENT OF EARTHING CONNECTIONS
39 - 3.8 PREVENTION OF CONTACT WITH LIVE PINS
39 - 3.8.1 During normal insertion
40 - 3.8.2 During other than normal insertion
40 - 3.8.3 Alignment of faceplates
40 - 3.9 FUSES
40 - 3.10 FLOOR SOCKET-OUTLETS
41 - 3.11 SWITCHED SOCKET-OUTLETS
41 - 3.11.1 Socket-outlets switched by insertion of plug pins
41 - 3.11.2 Socket-outlet switches
41 - 3.12 SHUTTERED SOCKET-OUTLETS
41 - 3.13 MARKING
41 - 3.13.1 Required marking
42 - 3.13.2 Location of marking
42 - 3.13.3 Earthing connections
42 - 3.13.4 Live connections
42 - 3.14 TESTS FOR SOCKET-OUTLETS
42 - 3.14.1 General
43 - 3.14.2 Insulation resistance test No. 1
44 - 3.14.3 High voltage test
44 - 3.14.4 Current breaking test
45 - 3.14.5 Test of temperature rise
46 - 3.14.6 Insulation resistance test No. 2
46 - 3.14.7 Test of earthing connection
46 - 3.14.8 Strength of contact tests
47 - 3.14.9 Switch test
47 - 3.14.10 Determination of IP rating
47 - 3.14.11 Determination of ignitability and combustion propagation
52 - APPENDIX A - GAUGE FOR THREE-PIN FLAT-PIN PLUGS
53 - APPENDIX B - GAUGE FOR TWO-PIN FLAT-PIN PLUGS WITH PARALLEL PINS
54 - APPENDIX C - THREE-PIN TEST PLUG WITH FLAT PINS FOR FULL-INSERTION TESTAND THE FINGER TEST DURING NORMAL INSERTION TEST
55 - APPENDIX D - THREE-PIN TEST PLUG WITH FLAT PINS FORABNORMAL INSERTION TEST
56 - APPENDIX E - PLUGS AND SOCKET-OUTLETS FOR USEIN EXTRA-LOW VOLTAGE CIRCUITS
56 - E1 GENERAL
56 - E2 DIMENSIONS AND RATING OF FLAT-PIN PLUGS
57 - APPENDIX F - GAUGE FOR FLAT AND ROUND PIN PLUGS
58 - APPENDIX G - THREE-PIN TEST PLUG WITH FLAT AND ROUND PINS FOR THEFULL-INSERTION TEST AND THE FINGER TEST DURINGNORMAL...
59 - APPENDIX H - DIMENSIONS FOR PLUGS AND SOCKET-OUTLETS, IP-RATED,WITH THREADED RETAINING DEVICES
60 - APPENDIX I - (VOID)
61 - APPENDIX J - EQUIPMENT WITH INTEGRAL PINS FOR INSERTION INTO SOCKET-OUTLETS
61 - J1 Scope
61 - J2 Requirements for the plug portion
61 - J2.1 Definition
61 - J2.2 Requirements

Specifies essential safety requirements for plugs and socket-outlets for approval and test purposes. It is intended to be read in conjunction with AS/NZS 3100.

Committee
EL-004
DocumentType
Standard
ISBN
0 7337 3267 4
Pages
57
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies essential safety requirements for plugs and socket-outlets, as defined in Clause 1.4, intended for use at extra-low or low voltages and a rated current not exceeding 32 A for household or similar purposes. (For extra-low voltage plugs and socket-outlets, see Appendix E.)This Standard does not apply to the following: (a) Appliance couplers (see AS/NZS 3109.1).(b) Installation couplers (see AS/NZS 3131).(c) Plugs, socket-outlets and couplers for general industrial applications (see AS/NZS 3123).

First published in Australia as AS C112-1937.
Redated 1938.
Redated 1939.
Second edition 1940.
Redated 1946.
Redated 1947.
Redated 1948.
Third edition 1951.
Redated 1955.
Fourth edition 1958.
Fifth edition 1964.
Revised and redesignated AS 3112-1981.
Second edition 1987.
Third edition 1990.
First published in New Zealand as part of NZSS 198-1939.
Second edition 1951.
Third edition 1958.
Fourth edition 1967.
NZSS 2147 first published 1967.
NZSS 198-1967 and NZSS 2147-1967 revised, amalgamated and redesignated in part as NZS 6216:1989.
AS 3112-1990 and NZS 6216:1989 jointly revised and designated Joint Standard AS/NZS 3112:1993.
Fifth edition 2000.

AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
AS/NZS 4695.2.11:1996 Fire hazard testing of electrotechnical products Test methods - Glow-wire end-product test and guidance
AS 1722.2-1992 Pipe threads of Whitworth form Fastening pipe threads (Reconfirmed 2017)
AS 2005.10-1988 Low voltage fuses - Fuses with enclosed fuse-links General requirements
AS 2005.30-1991 Low voltage fuses - Fuses with enclosed fuse-links Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications)
AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)

AS/NZS 3001:2001 Electrical installations - Relocatable premises (including caravans and tents) and their site installations
AS/NZS 3018:2001 Electrical installations - Domestic installations
AS/NZS 3123:2000 Approval and test specification - Plugs, socket-outlets and couplers for general industrial application
AS/NZS 3105:2002 Approval and test specification - Electrical portable outlet devices
AS/NZS 61558.2.6:2001 Safety of power transformers, power supply units and similar Particular requirements for safety isolating transformers for general use (IEC 61558-2-6:1997, MOD)
AS/NZS 61535.1(INT):2001 Installation couplers General requirements
AS/NZS 3131:2001 Approval and test specification - Plugs and socket-outlets for stationary appliances
AS 61010.1-2003 Safety requirements for electrical equipment for measurement, control and laboratory use General requirements (IEC 61010-1:2001, MOD)
AS/NZS 61347.2.2:2004 Lamp controlgear Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps (IEC 61347-2-2:2000 MOD)
AS/NZS 3002:2002 Electrical installations - Shows and carnivals
AS/NZS 60065:2003 Audio, video and similar electronic apparatus - Safety requirements (IEC 60065:2001, MOD)
AS/NZS 61535.1:2003 Installation couplers General requirements
AS/NZS 61009.1:2004 Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules (IEC 61009-1, Ed. 2.1 (2003) MOD)
AS/NZS 60745.1:2003 Hand-held motor-operated electric tools - Safety General requirements (IEC 60745-1:2001, MOD)
AS 60204.1-2005 Safety of machinery - Electrical equipment of machines General requirements (IEC 60204-1, Ed. 5 (FDIS) MOD)
AS/NZS 3160:2001 Approval and test specification - Hand-held portable electric tools
AS/NZS 60598.1:2003 Luminaires General requirements and tests (IEC 60598-1:2003, MOD)
AS/NZS 3199:2000 Approval and test specification for cord extension sets - Cord extension sets
AS/NZS 2500:2004 Guide to the safe use of electricity in patient care
AS/NZS 61008.1:2004 Residual current operated circuit breakers without integral overcurrent protection for household and similar uses (RCCBs) General rules (IEC 61008-1, Ed. 2.1 (2002) MOD)

£80.60